An image‐guided high intensity focused ultrasound device for uterine fibroids treatment
Notice bibliographique
Résumé
A high intensity focused ultrasound (HIFU) device was developed for treating uterine fibroid tumors. This prototype device enables image-guided therapy by aligning a commercially available abdominal ultrasound image probe to a vaginal HIFU transducer so the HIFU focus is in the image plane. The device was designed based on anatomical constraints of the female pelvic structures. HIFU was generated using a 3.5 MHz PZT-8 crystal, 25.4 mm in diameter, bonded to an aluminum lens. Computer simulations were performed to ensure that effective focusing was achievable at a fixed focal depth of 40 mm. Transducer efficiency was empirically determined to be 58%, and the half pressure maximum focal dimensions were 11 mm in length and 1.2 mm in width. A water-filled latex condom surrounding the transducer provided acoustic coupling, a stand-off, and allowed water circulation for transducer cooling. In vitro experiments in a tissue-mimicking gel phantom and in turkey breast demonstrated ultrasound image-guided lesion formation, or tissue necrosis, at the focus due to HIFU induced thermal and cavitation effects. The HIFU treatment site appeared as a hyperechoic spot on the ultrasound image at intensities above 1250 W/cm2. The results of in vitro experiments and in vivo ergonomic testing in six human volunteers indicated that the device has the potential of providing a nonsurgical approach for uterine fibroid treatment. Future in vivo studies in large animal models and fibroids patients are planned.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».