Corrosion Potential Sensor for Remote Monitoring of Civil Structure Based on Printed Circuit Board Sensor
Notice bibliographique
Résumé
We present a printed circuit board-based wireless inductively coupled corrosion potential sensor for monitoring corrosion of steel-reinforced concrete civil infrastructure. The sensor is a passive LC coil resonator whose resonant frequency varies owing to the corrosion potential produced by two electrodes connected across a voltage-controlled capacitor. The junction capacitance of the voltage-controlled capacitor also varies according to the potential generated by the two electrodes, which is in turn responsible for changing resonant frequency of the sensor. The two electrodes are a stainless steel reference electrode and a steel reinforcement electrode. An external interrogator coil coupled with the sensor coil monitors the sensor resonant frequency shift remotely by measuring the impedance change from the source end. The sensor has a sensitivity of ~1.2 kHz/mV both before and after it is embedded in the cement-based mortar used for testing the sensor. The sensor can be used to sense the corrosion susceptibility of existing structures by embedding the corrosion electrodes in new grout within a small slot formed in an existing structure. Using this approach, weight concentrations of NaCl mixed in cement-based mortars of greater than 2%-3% were detected. Accelerated corrosion tests on embedded sensors in simulations of both new and existing structure demonstrated corrosion potential resolution of less than 10 mV and an uncertainty of less than 50 mV. The sensor is simple in design, inexpensive, and passive making it a battery-less option for long-term corrosion monitoring, and widely deployable for civil structure.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».