MétaCan
Menu
Retour à la cohorte
Enregistrement W1981835394 · doi:10.1136/bjsports-2013-092459.5

UNILATERAL TENDON INJURY ACCELERATES TENDON MINERALISATION BILATERALLY AND RESULTS IN ALTERED TENDON FAILURE AND VISCOELASTIC PROPERTIES

2013· article· en· W1981835394 sur OpenAlexaff
E. J. O. O'Brien, Cyril B. Frank, Nigel G. Shrive, Benedikt Hallgrímsson, David A. Hart

Notice bibliographique

RevueBritish Journal of Sports Medicine · 2013
Typearticle
Langueen
DomaineMedicine
ThématiqueTendon Structure and Treatment
Établissements canadiensUniversity of Calgary
Organismes subventionnairesnon disponible
Mots-clésTendonMedicineAchilles tendonBiomechanicsHindlimbCreepAnatomyStiffnessMaterials science

Résumé

récupéré en direct d'OpenAlex

Introduction In humans, mineralised tendons are known to be weaker, possibly as a result of underuse due to pain. Underuse is also reported to cause an increase in hysteresis and a decrease in tendon stiffness. However, the impact of mineralisation on these other tendon properties is unknown. We have developed a needle-injury model which accelerates the spontaneous peritendinous mineralisation of murine Achilles tendons.1 Plain radiography suggests that unilateral injury accelerates mineralisation bilaterally. We hypothesised, therefore, that needle-injured murine Achilles tendons would show reduced strength and stiffness and increased creep (related to hysteresis) compared with contralateral non-injured tendons and tendons from non-injured controls. In addition, we hypothesised that unilateral injury would accelerate mineralisation bilaterally. Methods Ten week old male C57Bl/6 mice (Charles River) underwent left hind (LH) needle-injury and were sacrificed after 20 weeks along with non-injured controls. Hind limbs were examined by micro CT before testing isolated Achilles tendons using the following protocol: 30 cycles of loading between 0.23 and 4.5 N; 300 s dwell at 4.5 N; 495 s dwell at 0.23 N; and a ramp to failure at 5 mm/s. Creep was calculated as the percentage change in gauge length between the first loading peak and the end of the dwell at 4.5 N. Tangent stiffness was calculated from the slope of the force/displacement ramp to failure plot over the range 40–80% of failure force. Within and between group differences were examined using paired T and exact Mann-Whitney U tests respectively. Results Figure 1 shows that within injured individuals the volume of mineralisation was greater (p=0.01) in the LH compared with the right hind (RH) leg, and within non-injured individuals there was no difference between hind limbs (p=0.4). The volume of mineralisation was greater in the LH and RH of injured individuals compared with the respective limbs in non-injured individuals (both p=0.017). The mean failure force was lower (14.8±1.7 vs 16.7±0.7 N) and stiffness (22.9±2.7 vs 19.6±1.5N/mm) and creep (1.9±0.3 vs 3.1±1.2%) were higher in LH compared with RH limbs in six injured individuals (all P≤0.048). Differences between the mean values for seven LH limbs from injured (I) and three control individuals were not statistically significant for failure force (I=1.2 N lower, p=0.28), stiffness (I=3.5 N/mm higher, p=0.067) and creep (I=0.4% higher, p=0.067). All tendons failed close to the insertion except one injured tendon which failed partly in the mid substance and at the insertion. Figure 1. Mean volume (mm3) of peri-Achilles tendon mineralisation in injured (I, n=7) and control (C, n=3) animals. Discussion Unilateral needle-injury accelerated tendon mineralisation bilaterally. In humans, tendon mineralisation and other orthopaedic diseases often occur bilaterally, which may partly relate to interaction between contralateral limbs such as by altered loading of a non-injured limb, signal circulation or bilateral neurological effects of injury. The model presented here is therefore an excellent one to study this phenomenon. Needle-injured mineralised tendons were weaker (consistent with human clinical data), but stiffer and showed less creep than contralateral controls. This suggests that in patients, tendon mineralisation may alter limb function unless muscular adaptation occurs. Most injured and control tendons failed close to the insertion, in contrast to a report of similar tests in which most tendons from adult C57Bl/6J mice failed in the mid substance,2 perhaps explained by potential sub strain differences.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,004
Score d'incertitude au seuil0,012

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0010,000
Études des sciences et des technologies0,0000,001
Communication savante0,0000,000
Science ouverte0,0000,001
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0040,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,013
Tête enseignante GPT0,232
Écart entre enseignants0,219 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations1
Publié2013
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueBritish Journal of Sports MedicineMême sujetTendon Structure and TreatmentTravaux en français237 207