Continuous Intraocular Pressure (IOP) Measurement During Glaucoma Drainage Device Implantation
Notice bibliographique
Résumé
PURPOSE: To measure the effect of the implantation of a glaucoma drainage device on the intraocular pressure (IOP) during the implantation surgery. METHOD: We implanted telemetry devices into 1 eye each of 3 white New Zealand rabbits. Once the telemetry was found to be working and the rabbits had fully recovered from surgery, we implanted a glaucoma drainage device into the same eye while continually monitoring the IOP with the telemetry devices. RESULTS: During surgery IOP was extremely variable, however, extremely high pressures were recorded in association with suturing and viscoelastic injection. DISCUSSION: The fact that pressures are significantly raised during some surgical events should make surgeons aware that manipulations need to be kept as short as possible to prevent further potential damage to glaucomatous optic nerves. There is a possibility of dramatically raising the IOP during surgery, specifically in complicated cases requiring prolonged manipulation and/or forcible deepening of the anterior chamber. In such cases, it may be a good idea to time the duration of manipulations to prevent prolonged episodes of elevated IOP.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».