The coherency of ambient seismic noise recorded during land surveys and the resulting implications for the effectiveness of geophone arrays
Notice bibliographique
Résumé
ABSTRACT The use of analog sensor arrays is often assumed to provide signal-to-ambient-noise improvements proportional to the square root of the number of sensors being summed. We determined via numerical modeling and field experiments that the improvements sought were significantly hindered once the ambient noise exhibited coherence over the array being summed. As a first step, a numerical model was developed to explore the optimal sensor spacing based on the average correlation coefficient between sensors. Field experiments were then carried out to measure ambient noise using closely spaced geophones at several sites in Perth, Western Australia. We show that the measured noise at six test sites was strongly coherent over distances of up to 10 m, with the level of coherency being inversely proportional to frequency. The resulting optimum geophone spacing under our field conditions was determined to be 7.5 m. These results offered further encouragement to reassess our use of analog arrays and to consider recording the output from individual sensors. In addition to the benefits from postacquisition noise suppression, this approach will enable increased trace density without degradation of the signal caused by strong coherent noise sources over acquisition spreads.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».