The effect of radiometer placement and view on inferred directional and hemispheric radiometric temperatures of an urban canopy
Notice bibliographique
Résumé
Abstract. Any radiometer at a fixed location has a biased view when observing a convoluted, three-dimensional surface such as an urban canopy. The goal of this contribution is to determine the bias of various sensors views observing a simple urban residential neighbourhood (nadir, oblique, hemispherical) over a 24 hour cycle under clear weather conditions. The error in measuring a longwave radiation flux density (L) and/or inferring surface temperatures (T0) is quantified for different times over a diurnal cycle. Panoramic time-sequential thermography (PTST) data were recorded by a thermal camera on a hydraulic mast above a residential canyon in Vancouver, BC. The data set resolved sub-facet temperature variability of all representative urban facets in a 360° swath repetitively over a 24-hour cycle. This data set is used along with computer graphics and vision techniques to project measured fields of L for a given time and pixel onto texture sheets of a three-dimensional urban surface model at a resolution of centimetres. The resulting data set attributes L of each pixel on the texture sheets to different urban facets and associates facet location, azimuth, slope, material, and sky view factor. The texture sheets of L are used to calculate the complete surface temperature (T0,C) and to simulate the radiation in the field of view (FOV) of narrow and hemispheric radiometers observing the same urban surface (in absence of emissivity and atmospheric effects). The simulated directional (T0,d) and hemispheric (T0,h) radiometric temperatures inferred from various biased views are compared to T0,C. For a range of simulated off-nadir (φ) and azimuth (Ω) angles, T0,d(φ,Ω) and T0,C differ between −2.6 and +2.9 K over the course of the day. The effects of effective anisotropy are highest in the daytime, particularly around sunrise and sunset when different views can lead to differences in T0,d(φ,Ω) that are as high as 3.5 K. For a sensor with a narrow FOV in the nadir of the urban surface, T0,d(φ=0) differs from T0,C by +1.9 K (day) and by −1.6 K (night). Simulations of the FOV of hemispherical, downward-facing pyrgeometers at 270 positions show considerable variations in the measured L and inferred hemispherical radiometeric temperature T0,h as a function of both horizontal placement and height. The root mean squared error (RMSE) between different horizontal positions in retrieving outgoing longwave emittance L↑ decreased exponentially with height, and was 11.2, 6.3 and 2.0 W m−2 at 2, 3, and 5 times the mean building height zb. Generally, above 3.5zb the horizontal positional error is less than the typical accuracy of common pyrgeometers. The average T0,h over 24 h determined from the hemispherical radiometer sufficiently above an urban surface is in close agreement with the average T0,C. However, over the course of the day, the difference between T0,h and T0,C shows an RMSE of 1.7 K (9.4 W m−2) because the relative contributions of facets within the projected FOV of a pyrgeometer do not correspond to their fractions of the complete urban surface.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».