A Miscibility Scoping Study for Gas Injection into a High-Temperature Volatile Oil Reservoir in the Cooper Basin, Australia
Notice bibliographique
Résumé
Abstract As part of the Moomba Carbon Storage Project, a scoping study for the potential of miscible gas injection into Tirrawarra, an Australian onshore high temperature volatile oil reservoir, has been completed. Twenty-six injectants with varying compositions of CO2, CH4, C2H6, n-C5H12 and N2 are considered in the study. The volatile oil under study has a CO2 content of approximately 20 mol%. High temperature reservoirs and volatile oils are two extremes of a miscible gas injection system that have not commonly been studied in previous literature. The minimum miscibility pressure (MMP) between oil and an injectant is a key parameter in a miscible gas injection project, directly affecting project design. MMP is highly dependant on reservoir temperature as well as oil and injectant compositions. Commonly, MMP calculations involve one of the following three methods: (i) thermodynamic miscibility modeling, (ii) laboratory-based miscibility tests and simulations, (iii) use of correlations in the literature. In this study an Equation-of-State is used to facilitate 1-D slim tube simulations, through which the MMP between the volatile oil and various injectants is determined. Applying commonly used MMP correlations to our study reservoir provided poor results – with some correlations predicting MMP values at up to approximately 140% of those determined through 1-D slim tube simulation. This was due to the inability of many correlations to account for the effect of volatile oil composition and high reservoir temperatures. Our results show that MMP correlations can give misleading results if applied to reservoir data which is dissimilar to that with which the correlation was developed. The MMP with 100% CO2 injectant was calculated to be 2680 psig at 285°F. The highest MMP was obtained with pure N2 injectant at greater than 3600 psig. Variation of injectant composition had clear effects on the MMP. The increase of both N2 and CH4 concentrations in the injectant raised MMP by 25.6 psi/mol% and 15.2 psi/mol%, respectively. Increasing the C2H6 and n-C5H12 concentrations decreased MMP by 6.4 psi/mol% and 34.4 psi/mol%, respectively. The results of this study will help in developing an optimized injection strategy for the candidate reservoir, in addition to providing insights into key design parameters for surface facilities.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».