MétaCan
Menu
← tous les travaux

Continuous Multi-Parameter Heart Rate Variability Analysis Heralds Onset of Sepsis in Adults

2009· article· en· 297 citations· W1989415069 sur OpenAlex· 10.1371/journal.pone.0006642

Pourquoi ce travail est-il dans la base ?

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

Affiliation canadienneUne personne signataire a déclaré un établissement canadien. C'est la seule voie dont dispose la base habituelle.
Organisme subventionnaire canadienUn organisme canadien l'a financé. Le travail peut ne porter aucune affiliation canadienne.

Prédiction distillée sur la base complète

Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

Catégories candidates
aucune
Catégories consensuelles
aucune
Domaine
Signal candidat: aucuneSignal consensuel: aucune
Devis d'étude
Signal candidat: ObservationnelSignal consensuel: Observationnel
Genre
Signal candidat: EmpiriqueSignal consensuel: Empirique
Score de désaccord entre enseignants
0,164
Score d'incertitude au seuil
0,678
Statut de validation
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,001
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Tête enseignante Opus0,029
Tête enseignante GPT0,264
Écart entre enseignants
0,235 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validation
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Résumé

BACKGROUND: Early diagnosis of sepsis enables timely resuscitation and antibiotics and prevents subsequent morbidity and mortality. Clinical approaches relying on point-in-time analysis of vital signs or lab values are often insensitive, non-specific and late diagnostic markers of sepsis. Exploring otherwise hidden information within intervals-in-time, heart rate variability (HRV) has been documented to be both altered in the presence of sepsis, and correlated with its severity. We hypothesized that by continuously tracking individual patient HRV over time in patients as they develop sepsis, we would demonstrate reduced HRV in association with the onset of sepsis. METHODOLOGY/PRINCIPAL FINDINGS: We monitored heart rate continuously in adult bone marrow transplant (BMT) patients (n = 21) beginning a day before their BMT and continuing until recovery or withdrawal (12+/-4 days). We characterized HRV continuously over time with a panel of time, frequency, complexity, and scale-invariant domain techniques. We defined baseline HRV as mean variability for the first 24 h of monitoring and studied individual and population average percentage change (from baseline) over time in diverse HRV metrics, in comparison with the time of clinical diagnosis and treatment of sepsis (defined as systemic inflammatory response syndrome along with clinically suspected infection requiring treatment). Of the 21 patients enrolled, 4 patients withdrew, leaving 17 patients who completed the study. Fourteen patients developed sepsis requiring antibiotic therapy, whereas 3 did not. On average, for 12 out of 14 infected patients, a significant (25%) reduction prior to the clinical diagnosis and treatment of sepsis was observed in standard deviation, root mean square successive difference, sample and multiscale entropy, fast Fourier transform, detrended fluctuation analysis, and wavelet variability metrics. For infected patients (n = 14), wavelet HRV demonstrated a 25% drop from baseline 35 h prior to sepsis on average. For 3 out of 3 non-infected patients, all measures, except root mean square successive difference and entropy, showed no significant reduction. Significant correlation was present amongst these HRV metrics for the entire population. CONCLUSIONS/SIGNIFICANCE: Continuous HRV monitoring is feasible in ambulatory patients, demonstrates significant HRV alteration in individual patients in association with, and prior to clinical diagnosis and treatment of sepsis, and merits further investigation as a means of providing early warning of sepsis.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

La notice

Revue
PLoS ONE
Thématique
Heart Rate Variability and Autonomic Control
Domaine
Medicine
Établissements canadiens
University of OttawaOttawa Hospital
Organismes subventionnaires
Ottawa Hospital Research InstituteCanadian Institutes of Health ResearchUniversity of Ottawa
Mots-clés
SepsisMedicineHeart rate variabilityHeart ratePopulationInternal medicineSystemic inflammatory response syndromeResuscitationIntensive care medicineEmergency medicineBlood pressure
Résumé présent dans OpenAlex
oui