Anchorage of Titanium Implants with Different Surface Characteristics: An Experimental Study in Rabbits
Notice bibliographique
Résumé
PURPOSE: To compare the anchorage of titanium implants with different surface roughness and topography and to examine histologically the peri-implant bone after implant removal. MATERIALS AND METHODS: Screw implants with five different surface topographies were examined: (1) turned ("machined"), (2) TiO2-blasted with particles of grain size 10 to 53 microns; (3) TiO2-blasted, grain size 63 to 90 microns; (4) TiO2-blasted, grain size 90 to 125 microns; (5) titanium plasma-sprayed (TPS). The surface topography was determined by the use of an optical instrument. Twelve rabbits, divided into two groups, had a total of 120 implants inserted in the tibiae. One implant from each of the five surface categories was placed within the left tibia of each rabbit. By a second operation, implants were installed in the right tibia, after 2 weeks in group A and after 3 weeks in group B. Fluorochrome labeling was performed after 1 and 3 weeks. Removal torque (RMT) tests of the implants were performed 4 weeks after the second surgery in group A and 9 weeks after the second surgery in group B. Thus, in group A, two healing groups were created, representing 4 and 6 weeks, respectively. The corresponding healing groups in group B were 9 and 12 weeks. The tibiae were removed, and each implant site was dissected, fixed, and embedded in light-curing resin. Ground sections were made, and the peri-implant bone was analyzed using fluorescence and light microscopy. RESULTS: The turned implants had the lowest Sa and Sy values, whereas the highest scores were recorded for the TPS implants. The corresponding Sa and Sy values for the TiO2-blasted implants were higher when a larger size of grain particles had been used for blasting. At all four observation intervals, the TPS implants had the highest and the turned implants the lowest RMT scores. The differences between the various TiO2-blasted implants were, in general, small, but the screws with the largest Sa value had higher RMT scores at 6, 9, and 12 weeks than implants with lower Sa values. The histologic analysis of the sections representing 6, 9, and 12 weeks revealed that fractures or ruptures were present in the marginal, cortical peri-implant bone. In such sections representing the TPS and TiO2-blasted implant categories, ruptures were frequently found in the zone between the old bone and the newly formed bone, as well as within the newly formed bone. CONCLUSIONS: The present study demonstrated that a clear relation exists between surface roughness, described in Sa values, and implant anchorage assessed by RMT measurements. The anchorage appeared to increase with the maturation of bone tissue during healing.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».