New Predictive Methodology for the Onset of Flow Instability in Single Horizontal Microtube With an Inlet Orifice
Notice bibliographique
Résumé
A new methodology to predict the onset of flow instability (OFI) in single horizontal microtube with inlet orifice is proposed. The predictive methodology states that OFI occurs as the pumping power under no heating condition is equal to the pumping power under heating condition in the microtube at the same volume rate. Since the pumping power can be simply described as the product of volume rate and pressure drop cross the microtube, the heat flux at OFI is determined as the two-phase pressure drop under heating condition is equal to the single-phase pressure drop under no heating condition at same flow rate. The addition of inlet orifice increases the pumping power under no heating condition. The increased pumping power by orifice delays the onset of flow instability. The predictive methodology is validated by comparing the predicted heat flux at OFI with our previous experimental data in the microtubes with three different inlet restriction ratios. The result shows that the proposed method is capable of prediction of heat flux at OFI with a deviation of 30% and mean absolute error of 13% at mass flux less than 2000 kg/m2·s.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».