Dosimetric properties of an amorphous‐silicon EPID used in continuous acquisition mode for application to dynamic and arc IMRT
Notice bibliographique
Résumé
Dosimetric properties of an amorphous-silicon electronic portal imaging device (EPID) operated in a real-time acquisition mode were investigated. This mode will be essential for time-resolved dose verification of dynamic (sliding window) intensity modulated radiation therapy (IMRT) and intensity modulated arc radiation therapy (arc-IMRT). The EPID was used in continuous acquisition mode (i.e., "cine" mode) where individual sequential image frames are acquired in real time. The properties studied include dose linearity, reproducibility of response, and image stability. Results of using the continuous acquisition mode with several example treatments including dynamic IMRT, arc treatment, and single-arc-IMRT are compared to results using the well-studied integrated acquisition mode (i.e., "frame averaging" or "IMRT" mode). Real-time EPID response was also compared to real-time ion-chamber data for selected points in the deliveries. The example treatment deliveries in both continuous and integrated acquisition modes were converted to arbitrary EPID dose units via a calibration field. The summation of all acquired continuous mode images was compared using percentage dose difference to the single image acquired in the integrated mode using in-field pixels only (defined as those pixels > 10% of maximum, in-field signal). Using the continuous acquisition mode, the EPID response was not linear with dose. It was found that the continuous mode dose response corresponded approximately to dropping one image per acquisition session. Reproducibility of EPID response to low monitor units (MUs) was found to be poor but greatly improved with increasing MU. Open field profiles were found to be stable in the cross-plane direction but required several frames to become stable in the in-plane direction. However, both of these issues are clinically insignificant due to arc-IMRT deliveries requiring relatively large monitor units (> 100 MU). Analysis of the five IMRT, arc, and arc-IMRT tests revealed that all examples compared to within 2% of maximum dose for more than 95% of in-field pixels. The continuous acquisition mode is suited to time-resolved dosimetry applications including arc-IMRT and dynamic IMRT, giving comparable dose results to the well-studied integrated acquisition mode, although caution should be used in low MU applications. Time-resolved EPID dose information also compared well to time-resolved ion-chamber measurements.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».