Enhancement of Electrochemical Capacitance by Doping Rod-Like Mn Oxide Electrodes with Co
Notice bibliographique
Résumé
The electrochemical properties of nanocrystalline Mn oxide and Mn-Co doped oxide electrodes, with and without a conducting polymer (PEDOT) coating, were investigated to determine the effect of morphology, chemistry and crystal structure on the corresponding electrochemical behavior of synthesized electrodes. Mn-Co oxide electrodes with rod-like structures were synthesized electrochemically by anodic deposition from an electrolyte solution of Mn acetate and Co sulfate on Au coated Si substrates. The electrochemical behavior of the deposits was studied by cyclic voltammetry at different scan rates. Also, microstructural characterization of as-deposited and cycled electrodes was conducted using SEM. The Mn-Co oxide/PEDOT electrodes showed improved specific capacity and electrochemical cyclability relative to uncoated Mn oxide, Mn-Co oxide and Mn oxide/PEDOT electrodes. A specific capacitance of ~310 Fg−1, with a capacitance retention of 92% of the original value, was obtained for Mn-Co/PEDOT electrodes after 250 cycles in 0.5M Na2SO4 at 100 mVs−1.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».