Analysis of powdered reference materials and known samples with a benchtop, field portable X-ray fluorescence (pXRF) spectrometer: evaluation of performance and potential applications for exploration lithogeochemistry
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Powdered international reference materials and samples with previously obtained conventional geochemical data were analysed using a benchtop portable X-ray fluorescence (pXRF) spectrometer to test the abilities of pXRF in silicate rock lithogeochemistry. Results from international reference materials illustrate that pXRF can provide very precise data for many major, minor, and trace elements, generally with RSD values of <7.5 % and many <5 %, except at very low concentrations (i.e. approaching the limit of detection). Despite good precision, accuracy is highly variable and ranges from excellent to reasonable for many major and minor elements (±15–20 % relative difference, RD, for Al 2 O 3 , SiO 2 , K 2 O, CaO, Fe 2 O 3 , TiO 2 , and MnO±S), base metals (±20 % for Cu, Zn), the low field strength (LFSE) and high field strength elements (HFSE) (±15 % RD for Rb, Ba, Zr; ±20 % RD for Nb). Poor accuracy was obtained for MgO, P 2 O 5 , and the transition elements (V, Cr, Ni); Sr shows variable accuracy. Comparison of pXRF results to independent samples with data from conventional analyses illustrates very poor correlation for MgO, P 2 O 5 , V, Cr, and Ni, suggesting they have poor accuracy by pXRF. Aluminum (Al 2 O 3 ), SiO 2 , and Zn have r 2 values of c . 0.6–0.7 illustrating reasonable correlation, whereas most other elements (S, K 2 O, CaO, TiO 2 , MnO, Fe 2 O 3 , Co, Cu, Pb, Rb, Sr, Ba, Zr, Nb, U, As, and Mo) have very good to excellent correlation between pXRF data and conventional analysis (i.e. r 2 >0.80). In addition, many of the elements with r 2 >0.8 have slopes that are close to 1 or within 20 % of ideal, indicating that pXRF is replicating the results of conventional analyses and likely within ±20 % of what can be obtained by conventional methods. Down-hole profiles of pXRF data and element ratios replicate the geometry of the profiles from conventional analyses and illustrate the ability of the pXRF to discriminate rock type, alteration, and mineralization in unknown samples. Portable XRF can provide fit-for-purpose data that is useful in discriminating lithogeochemical variations related to lithology, alteration, and mineralization. However, pXRF should be considered a preliminary screening tool for sample selection and not a substitute for conventional lithogeochemical methods (e.g. XRF, fusion ICP-ES and ICP-MS), particularly when important economic decisions are to be made using such data (e.g. NI-43-101 resource calculations). Supplementary Material: Collated data for repeat analyses of reference materials in Mining Plus (Table 1) and Soil 3 Beam (Table 2) modes. Tables 3-9 contain plots comparing results from pXRF to accepted values for various reference materials. All tables are available at at www.geolsoc.org.uk/SUP18735
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle