Barriers and Facilitators to Intraosseous Access in Adult Resuscitations When Peripheral Intravenous Access Is Not Achievable
Notice bibliographique
Résumé
OBJECTIVES: Studies suggest that intraosseous (IO) access is underutilized in adult resuscitations, despite recommendations from advanced trauma and cardiac life support guidelines. The objective was to determine factors associated with IO access use by physicians during adult resuscitations when intravenous (IV) access is not immediately achievable. METHODS: This study was an online survey among physicians purposefully recruited from various clinical care areas at three teaching hospitals. Questions were generated from the qualitative results of 20 iterative interviews, verified for internal validity, and piloted. The interview guide was based on the constructs of the Theory of Planned Behavior (TPB), which elicits salient attitudes, social influences, and control beliefs that potentially influence intention to use IO access. Recruitment took place in September 2012 until reaching more than 100% of the required sample size (n = 200). Internal consistency was measured using Cronbach's alpha, and the effect of TPB constructs and specific beliefs were assessed with regression analyses. RESULTS: For the 205 respondents, the mean age was 35 years (range = 20 to 66 years), and 53.3% were male. Participants' departmental affiliations were 50.3% emergency medicine (EM), 16.9% internal medicine, 14.9% anesthesia, 10.8% general surgery, and 7.2% critical care. Residents comprised 60.7% of the sample, and 39.3% were attending physicians. Median intention to use IO access when IV is not immediately achievable was 4.67 (interquartile range [IQR] = 4 to 5) out of 5 (5 highest) and predicted by the following TPB constructs: attitudes (AdjCoefficients = 0.504; 95% confidence interval [CI] = 0.334 to 0.673), social influences (AdjCoefficients = 0.285; 95% CI = 0.172 to 0.398), and control beliefs (AdjCoefficients 0.217; 95% CI = 0.113 to 0.320). Physicians were more likely to use IO access if they believed that it provided rapid vascular access for delivering large volumes of fluids, could prevent delays in care, and was associated with a low complication rate. Conversely, the perception that nurses are not familiar or supportive of IO access and a lack of physician confidence regarding the appropriate indications for IO access were barriers to use. CONCLUSIONS: These data are an important step in the knowledge-to-action process, as they identify specific factors associated with physician use of IO access. Interventions addressing these actionable facilitators and barriers are likely to have a positive effect on increasing the appropriate physician use of this potentially life-saving technique in adult patients requiring emergent vascular access.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,025 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».