Improving signal‐to‐noise ratio of hyperpolarized noble gas MR imaging at 73.5 mT using multiturn Litz wire radiofrequency receive coils
Notice bibliographique
Résumé
Abstract Hyperpolarized noble gases ( 3 He, 129 Xe) are used in Magnetic Resonance imaging as inhaled contrast agents to visualize the lung. Because the magnetization derived from hyperpolarization is independent of magnetic field strength, low magnetic fields can be used, where coil noise dominates over sample noise. It has been shown previously that signal‐to‐noise ratio (SNR) of hyperpolarized 129 Xe rat lung images can be improved with the use of saddle‐shaped radiofrequency receive coils constructed of Litz wire in a single layer with up to 20 turns. Increased number of turns is expected to provide additional sensitivity. In this work, coils of the same geometry were built using Litz wire with either the addition of more turns (up to 48) or the addition of two layers and compared using water phantoms. It is shown that the addition of 48 turns in a single layer provided a 42% increase in SNR, when compared to the 20 turns, whereas the dual‐layered approach provided no measurable benefit. © 2011 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 39B:37–42, 2011
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».