Multiple Auditory Steady-State Response Thresholds to Bone-Conduction Stimuli in Young Infants with Normal Hearing
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
In Brief Objective: Multiple auditory steady-state responses (ASSRs) probably will be incorporated into the diagnostic test battery for estimating hearing thresholds in young infants in the near future. Limiting this, however, is the fact that there are no published bone-conduction ASSR threshold data for infants with normal or impaired hearing. The objective of this study was to investigate bone-conduction ASSR thresholds in infants from a Neonatal Intensive Care Unit (NICU) and in young infants with normal hearing and to compare these with adult ASSR thresholds. Design: ASSR thresholds to multiple bone-conduction stimuli (carrier frequencies: 500 to 4000 Hz; 77 to 101-Hz modulation rates; amplitude/frequency modulated; single-polarity stimulus) were obtained in two infant groups [N = 29 preterm (32 to 43 wk PCA), tested in NICU; N = 14 postterm (0 to 8 mo), tested in sound booth]. All infants had passed a hearing screening test. ASSR thresholds, amplitudes, and phase delays for preterm and postterm infants were compared with previously collected adult data. Results: Mean (±1 SD) ASSR thresholds were 16 (11), 16 (10), 37 (10), and 33 (13) dB HL for the preterm infants and 14 (13), 2 (7), 26 (6), and 22 (8) dB HL for the postterm infants at 500, 1000, 2000, and 4000 Hz, respectively. Both infant groups had significantly better thresholds for 500 and 1000 Hz compared with 2000 and 4000 Hz, in contrast to adults who have similar thresholds across frequency (22, 26, 18, and 18 dB HL). When 500- and 1000-Hz thresholds were pooled, pre- and postterm infants had better low-frequency thresholds than adults. When 2000- and 4000-Hz thresholds were pooled, pre- and postterm infants had poorer thresholds than adults. ASSR amplitudes were significantly larger for low frequencies compared with high frequencies for both infant groups, in contrast to adults, who show little difference across frequency. ASSR phase delays were later for lower frequencies compared with higher frequencies for infants and adults, except for 500 Hz in the preterm group. ASSR phase delays were later for infants compared with adults across frequency. Conclusions: Infant bone-conduction ASSR thresholds are very different from those of adults. Overall, these results indicate that low-frequency bone-conduction thresholds worsen and high-frequency bone-conduction thresholds improve with maturation. Bone-conduction ASSR threshold differences between the postterm infants and adults probably are due to skull maturation. Differences between preterm and older infants may be explained both by skull changes and a masking effect of high ambient noise levels in the NICU (and possibly to other issues due to prematurity). Multiple auditory steady-state responses (ASSRs) will likely be incorporated into the diagnostic test battery for estimating hearing thresholds in young infants in the near future. The objective of this study was to record bone-conduction ASSRs in two groups of young infants with normal hearing. ASSR thresholds, amplitudes and phase delays for pre- and post-term infants were compared to previously collected adult data. Infant bone-conduction ASSRs are very different from those of adults. Both infant groups had significantly better thresholds and larger amplitudes for low frequencies compared to high frequencies, in contrast to adults who have similar thresholds and amplitudes across frequency. Low-frequency ASSR thresholds were better while high-frequency ASSR thresholds were worse for infants compared to adults. These results indicate that low-frequency bone-conduction thresholds worsen and high-frequency bone-conduction thresholds improve with maturation. These differences in bone-conduction ASSR thresholds and amplitudes between the infants and adults are likely due primarily to skull maturation.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle