MétaCan
Menu
Retour à la cohorte
Enregistrement W1998725904 · doi:10.1007/s11999-014-3804-6

Systematic Review of Patient-specific Instrumentation in Total Knee Arthroplasty: New but Not Improved

2014· review· en· W1998725904 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

aboutLe titre ou le résumé porte un signal canadien du lexique géographique.
no affAucune affiliation canadienne : ce travail est invisible pour une base fondée sur la seule affiliation.
Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Notice bibliographique

RevueClinical Orthopaedics and Related Research · 2014
Typereview
Langueen
DomaineMedicine
ThématiqueTotal Knee Arthroplasty Outcomes
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésMedicineMEDLINEInstrumentation (computer programming)Evidence-based medicinePhysical therapyTotal knee arthroplastyArthroplastyMedical physicsSurgeryComputer science

Résumé

récupéré en direct d'OpenAlex

BACKGROUND: Patient-specific cutting blocks have been touted as a more efficient and reliable means of achieving neutral mechanical alignment during TKA with the proposed downstream effect of improved clinical outcomes. However, it is not clear to what degree published studies support these assumptions. QUESTIONS/PURPOSES: We asked: (1) Do patient-specific cutting blocks achieve neutral mechanical alignment more reliably during TKA when compared with conventional methods? (2) Does patient-specific instrumentation (PSI) provide financial benefit through improved surgical efficiency? (3) Does the use of patient-specific cutting blocks translate to improved clinical results after TKA when compared with conventional instrumentation? METHODS: We performed a systematic review in accordance with Cochrane guidelines of controlled studies (prospective and retrospective) in MEDLINE® and EMBASE® with respect to patient-specific cutting blocks and their effect on alignment, cost, operative time, clinical outcome scores, complications, and survivorship. Sixteen studies (Level I-III on the levels of evidence rubric) were identified and used in addressing the first question, 13 (Level I-III) for the second question, and two (Level III) for the third question. Qualitative assessment of the selected Level I studies was performed using the modified Jadad score; Level II and III studies were rated based on the Newcastle-Ottawa scoring system. RESULTS: The majority of studies did not show an improvement in overall limb alignment when PSI was compared with standard instrumentation. Mixed results were seen across studies with regard to the prevalence of alignment outliers when PSI was compared with conventional cutting blocks with some studies demonstrating no difference, some showing an improvement with PSI, and a single study showing worse results with PSI. The studies demonstrated mixed results regarding the influence of PSI on operative times. Decreased operative times were not uniformly observed, and when noted, they were found to be of minimal clinical or financial significance. PSI did reliably reduce the number of instrument trays required for processing perioperatively. The accuracy of the preoperative plan, generated by the PSI manufacturers, was found lacking, often leading to multiple intraoperative changes, thereby disrupting the flow of the operation and negatively impacting efficiency. Limited data exist with regard to the effect of PSI on postoperative function, improvement in pain, and patient satisfaction. Neither of the two studies we identified provided strong evidence to support an advantage favoring the use of PSI. No identified studies addressed survivorship of components placed with PSI compared with those placed with standard instrumentation. CONCLUSIONS: PSI for TKA has not reliably demonstrated improvement of postoperative limb or component alignment when compared with standard instrumentation. Although decisive evidence exists to support that PSI requires fewer surgical trays, PSI has not clearly been shown to improve overall surgical efficiency or the cost-effectiveness of TKA. Mid- and long-term data regarding PSI's effect on functional outcomes and component survivorship do not exist and short-term data are scarce. Limited available literature does not clearly support any improvement of postoperative pain, activity, function, or ROM when PSI is compared with traditional instrumentation.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,007
score de la tête « metaresearch » (Gemma)0,008
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict), Intégrité de la recherche
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Revue systématique · Signal consensuel: Revue systématique
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,391
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0070,008
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0060,001
Bibliométrie0,0010,001
Études des sciences et des technologies0,0000,001
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0010,004
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,071
Tête enseignante GPT0,413
Écart entre enseignants0,342 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle