Sensitivity Analysis of the Response of a Gas Sensor in a Microfluidic-Based Gas Analyzer
Notice bibliographique
Résumé
Gas sensors have been used as the detection unit of gas analyzers. A low-cost and easy to fabricate gas analyzer can be made by integration a general purpose gas sensor with a microfluidic channel on a polymer substrate. However, ambient fluctuations influence the gas sensor characteristics and operation. In essence, these devices are vulnerable to drift since the interaction of the sensing pallet of the gas sensor with the surrounding air is a temperature- and humidity-dependent process which introduces drift terms to the output signal. These drift terms can also be considered as a controllable input while the sensor itself is considered as a multiple input and output system. In the present study, a methodology based on statistical techniques is introduced to perform the sensitivity analysis and to determine the contribution of each of the input parameters in the output response of the sensor used in a gas analyzer. A regression model is also applied to predict the response of the sensor to the temperature, humidity and the gas concentration values that have not been experimentally tested. Also, the effect of these environmental conditions on the three mentioned factors is studied using design of experiments (DOX) methods.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».