A Computed Tomographic Scan–Derived Customized Surgical Template and Fixed Prosthesis for Flapless Surgery and Immediate Loading of Implants in Fully Edentulous Maxillae: A Prospective Multicenter Study

2005· article· en· 337 citations· W2001174076 sur OpenAlex· 10.1111/j.1708-8208.2005.tb00083.x

Pourquoi ce travail est-il dans la base ?

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

Revue canadienneIl a paru dans une revue canadienne.

Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Scores machine (provisoires)

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Tête enseignante Opus0,090
Tête enseignante GPT0,431
Écart entre enseignants
0,341 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validation
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Résumé

BACKGROUND: Based on three-dimensional implant planning software for computed tomographic (CT) scan data, customized surgical templates and final dental prostheses could be designed to ensure high precision transfer of the implant treatment planning to the operative field and an immediate rigid splinting of the installed implants, respectively. PURPOSE: The aim of the present study was to (1) evaluate a concept including a treatment planning procedure based on CT scan images and a prefabricated fixed prosthetic reconstruction for immediate function in upper jaws using a flapless surgical technique and (2) validate the universality of this concept in a prospective multicenter clinical study. MATERIALS AND METHODS: Twenty-seven consecutive patients with edentulous maxillae were included. Treatments were performed according to the Teeth-in-an-Hour concept (Nobel Biocare AB, Göteborg, Sweden), which includes a CT scan-derived customized surgical template for flapless surgery and a prefabricated prosthetic suprastructure. RESULTS: All patients received their final prosthetic restoration immediately after implant placement, that is, both the surgery and the prosthesis insertion were completed within approximately 1 hour. In the 24 patients followed for 1 year, all prostheses and individual implants were recorded as stable. CONCLUSION: The present prospective multicenter study indicates that the prefabrication, on the basis of models derived from three-dimensional oral implant planning software, of both surgical templates for flapless surgery and dental prostheses for immediate loading is a very reliable treatment option. It is evident that the same approach could be used for staged surgery and in partial edentulism.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

La notice

Revue
Clinical Implant Dentistry and Related Research
Thématique
Dental Implant Techniques and Outcomes
Domaine
Dentistry
Établissements canadiens
Organismes subventionnaires
Mots-clés
EdentulismMedicineMaxillaProsthesisDentistryImplantDental prosthesisRadiation treatment planningOrthodonticsSurgeryRadiation therapy
Résumé présent dans OpenAlex
oui