On the parameters affecting the sensitivity of MR measures of pressure with microbubbles
Notice bibliographique
Résumé
Recently, it has been suggested that gas encapsulated distensible microbubbles may serve as pressure probes in the MR field through the relationship between bubble size and 1/T(2) or 1/T(*)(2). Currently, in vivo application of this technique is hindered by the ability of T(2) or T(*)(2) to detect pressure changes that are clinically relevant. This work identifies and characterizes, through numerical simulations, the set of parameters which optimize the ability of this technique to detect small pressure changes. Results show that when the bubbles do not interact magnetically, the T(2)- and T(*)(2)-based measurements of pressure are strongly influenced by the bubble size at atmospheric pressure, static magnetic field strength, magnitude of the susceptibility difference between the encapsulated gas and plasma, bubble volume fraction, and the refocusing interval. In particular, to detect clinically relevant pressure changes, microbubbles need to be approximately 2-3 microm in radius, distributed at a volume fraction of 0.15%, and have a volumetric magnetic susceptibility difference of at least 34 ppm.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».