MétaCan
Menu
Retour à la cohorte
Enregistrement W2002669476 · doi:10.1097/aud.0b013e3181d4f228

Lateralization of Interimplant Timing and Level Differences in Children Who Use Bilateral Cochlear Implants

2010· article· en· W2002669476 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

affAu moins un auteur déclare une institution canadienne dans l'instantané OpenAlex épinglé.

Notice bibliographique

RevueEar and Hearing · 2010
Typearticle
Langueen
DomaineNeuroscience
ThématiqueHearing Loss and Rehabilitation
Établissements canadiensHospital for Sick ChildrenToronto Rehabilitation InstituteUniversity of Toronto
Organismes subventionnairesnon disponible
Mots-clésLateralization of brain functionAudiologyCochlear implantCochlear implantationMedicinePsychology

Résumé

récupéré en direct d'OpenAlex

In Brief Objectives: Interaural level differences (ILD) and interaural timing differences (ITD) are important cues for locating sounds in space. Adult bilateral cochlear implant (CI) users use ILDs more effectively than ITDs. Few studies investigated the ability of children who use bilateral CIs to make use of these binaural cues. Our working hypothesis was that children using bilateral CIs are able to perceive changes in ITDs and ILDs similar to their normal-hearing (NH) peers. Design: Participants were two groups of children; 19 bilateral implant users (CI) and nine NH children. The children in the CI group had received a second CI after 4.9 ± 2.8 yrs of unilateral use. Children performed a four alternative forced-choice lateralization task in which they were asked to describe stimuli as coming from the left side, right side, middle of the head, or from both sides simultaneously. Stimuli were 500 msec trains of electrical pulses delivered to apical electrode no. 18 (CI group) or clicks (NH group) presented 11 times per second with either ITDs (0, 400, 1000, or 2000 μsec delay between sides) or level differences (0, 10, or 20 Current Units (CI group) or 0, 10, or 20 dB (NH group) difference between sides). ITDs were presented using current levels that were balanced using left and right electrically evoked brain stem responses. Stimulus levels evoking response amplitudes that were most similar were used. Results: Responses from children in the CI group changed significantly with changes in ILD of bilateral stimuli, but not with changes in ITD. Responses from children in the CI group were significantly different from those in the NH group in three ways. Children in the CI group perceived bilaterally presented electrical pulses: (1) to come from the second implanted side more often than the first, (2) to rarely come from the middle, and (3) to come from both sides of the head simultaneously. Perceived changes in lateralization with ILD changes were correlated with differences in amplitudes of electrically evoked brain stem responses by the left versus right CI. Conclusions: The results of this study illustrate that children who use bilateral CIs can lateralize stimuli on the basis of level cues, but have difficulty interpreting interimplant timing differences. Perceived lateralization of bilaterally presented stimuli to the second implanted side in many of the stimulus conditions may relate to the use of different device generations between sides. Further differences from normal lateralization responses could be due to abnormal binaural processing, possibly resulting from a period of unilateral hearing before the provision of a second implant or due to insufficiently matched interimplant stimuli. It may be possible to use objective measures such as electrically evoked auditory brain stem responses wave eV amplitudes to provide balanced levels of bilateral stimulation in children who have had no binaural hearing experience. Interaural level and timing cues are necessary to locate sound in space. We investigated whether children using bilateral cochlear implants (CIs) could interpret these cues. Children using bilateral CIs detected interimplant level cues but abnormalities included the following: 1) no significant changes in responses with changes in interimplant timing cues, 2) a predominance of responses towards the side of the second CI, 3) minimal “middle” responses, and 4) perception of sound from both sides simultaneously. We suggest that children receiving bilateral cochlear implants sequentially do not process bilateral auditory cues normally but can use interimplant level cues to make judgments about where sound is coming from.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,344
Score d'incertitude au seuil0,195

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,087
Tête enseignante GPT0,294
Écart entre enseignants0,207 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle