Interference of implanted cardiac pacemakers with TASER X26 dart mode application
Notice bibliographique
Résumé
The prevalence of pacemaker patients among the general population and of conducted energy devices for law enforcement and self-defence is increasing. Consequently, the question on whether cardiac pacemaker patients are at particular risk becomes increasingly important, in particular, as the widespread use of such devices is planned in Europe. The risk of pacemaker patients has been investigated by numerical simulation at detailed anatomical models of patients with cardiac pacemakers implanted in left pectoral, right pectoral, and abdominal positions, with the monopolar electrode placed at the ventricular apex. The induced cardiac pacemaker interference voltages have been assessed for distant application of TASER X26 devices with dart electrodes propelled towards a subject. It could be shown that interference voltages are highest in abdominal pacemaker implantation, while they are about 20% lower in left or right pectoral sites. They remain below the immunity threshold level as defined by safety standards of implanted cardiac pacemakers and of implanted cardioverter defibrillators to prevent persisting malfunction or damage. However, induced voltages are high enough to be sensed by the pacemaker and to capture pacemaker function in case of hits at thorax and abdomen, frontal as well as dorsal.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».