MétaCan
Menu
Retour à la cohorte
Enregistrement W2004482861 · doi:10.1097/00005131-200207000-00008

The Biomechanical Effect of High-Pressure Irrigation on Diaphyseal Fracture Healing In Vivo

2002· article· en· W2004482861 sur OpenAlexaff
Anthony Adili, Mohit Bhandari, Emil H. Schemitsch

Notice bibliographique

RevueJournal of Orthopaedic Trauma · 2002
Typearticle
Langueen
DomaineMedicine
ThématiqueBone fractures and treatments
Établissements canadiensSt. Michael's HospitalUniversity of TorontoMcMaster University
Organismes subventionnairesnon disponible
Mots-clésMedicineIntramedullary rodPulsatile flowBone healingClosed FractureDebridement (dental)FemurSurgeryBiomechanicsIn vivoBiomedical engineeringAnatomyInternal medicineBiology

Résumé

récupéré en direct d'OpenAlex

OBJECTIVES: To evaluate the effect of both high-pressure pulsatile lavage and bulb syringe irrigation on the biomechanical parameters of fracture healing using an in vivo open noncontaminated diaphyseal femoral fracture model in rats. BACKGROUND: The utility of high-pressure pulsatile lavage irrigation on soft tissue debridement has been extrapolated to a similar perceived benefit in the debridement of bone. However, there have been several reports of a possible deleterious effect that high-pressure pulsatile lavage may have on bone architecture, intramedullary bacterial and contaminant seeding, and fracture healing. Although a previous in vivo histologic study suggests damage to bone architecture and impairment of early bone formation, it remains unclear whether these microscopic findings translate to a detectable decline in the biomechanical strength of the healing fracture. To our knowledge, there have been no reports of the in vivo effects high-pressure pulsatile lavage on fracture healing in open diaphyseal fractures. MATERIALS AND METHODS: Using sterile technique, standard open transverse mid-shaft femur fractures were created in thirty-six rats randomized into three groups: a control group underwent retrograde intramedullary pinning only; a bulb syringe irrigation group and a high-pressure pulsatile lavage group underwent identical procedures as the control group, except that the osteotomy site was irrigated with bulb syringe irrigation and high-pressure pulsatile lavage, respectively, before insertion of the intramedullary pin. Six rats from each group were killed at three weeks and six weeks, and the femora was mechanically tested in bending. RESULTS: Mechanical testing of the thirty-six femora revealed that the peak bending force (17.7 +/- 10.2 N) and stiffness (21.2 +/- 5.1 N/mm) of the healing fracture in the high-pressure irrigation group were significantly lower at three weeks when compared with the control (peak force, 28.1 +/- 5.9 N; stiffness, 31.4 +/- 5.8 N/mm) and the bulb syringe (peak force, 27.7 +/- 3.3 N; stiffness, 23.6 +/- 4.5 N/mm) irrigation groups (p < 0.05). The 37 percent lower peak bending force and 32 percent lower stiffness in the high-pressure pulsatile lavage group after three weeks of fracture healing were not present in the femora tested at six weeks. The high-pressure pulsatile lavage group did reveal a trend toward a lower peak bending force and stiffness after six weeks of fracture healing when compared with the control and bulb syringe irrigation groups, but the differences were not statistically significant at the 95 percent level. CONCLUSIONS: The use of high-pressure pulsatile lavage in open noncontaminated diaphyseal femur fractures in rats has a significant negative impact on the mechanical strength of the fracture callous during the early phases (three weeks) of fracture healing. However, it appears that the early deleterious effect of high-pressure pulsatile irrigation is not apparent in the late phases (six weeks) of fracture healing. Further study is required to evaluate the effect of high-pressure pulsatile lavage on fracture healing in the presence of wound contamination, fracture comminution, and soft tissue damage. CLINICAL SIGNIFICANCE: The findings of this study suggest that selective use of high-pressure irrigation in the management of open fractures appears warranted. In situations in which high-pressure lavage may be deleterious to bone healing, alternative strategies that optimize bacterial removal from soft tissues while preserving bone architecture will need to be investigated.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,827
Score d'incertitude au seuil0,325

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,013
Tête enseignante GPT0,270
Écart entre enseignants0,257 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations61
Publié2002
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJournal of Orthopaedic TraumaMême sujetBone fractures and treatmentsTravaux en français237 207