Multimodality intraoperative monitoring during complex lumbosacral procedures: indications, techniques, and long-term follow-up review of 61 consecutive cases
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
OBJECT: The purpose of this study was to examine the neurological outcomes after complex lumbosacral surgery in patients undergoing multimodality neurophysiological monitoring. METHODS: Sixty-one patients were consecutively enrolled in this study. These patients underwent complex intra- and extradural lumbosacral procedures with concomitant intraoperative electromyography (EMG) monitoring of the lower-limb muscles, external anal and urethral sphincters (EAS and EUS), and lower-limb somatosensory evoked potentials (SSEPs). Long-term (minimum 2-year) clinical follow-up data were obtained in all cases. Most patients were treated for spinal/spinal cord tumors (61%) or adult tethered cord syndrome (25%). Recordable lower-extremity SSEPs were reported in 54 patients (89%). New postoperative neurological deficits occurred in only three patients (4.9%), and remained persistent in only one patient (1.6%) at long-term follow-up examination. In only one of these cases was a significant decrease in SSEP amplitude detected. Spontaneous EMG activity was observed in the lower-extremity muscles and/or EAS and EUS in 51 cases (84%). Intraoperatively, EMG demonstrated activity only in the EUS in 5% of patients and only in the EAS in 28%. In seven patients (11%) spontaneous intraoperative EMG activity was observed in both the EAS and the EUS; however, in only three of these cases was EMG activity recorded in both sphincters simultaneously. In addition to spontaneously recorded EMG activity, electrically evoked EMG activity was also used as an intraoperative adjunct. A bipolar stimulating electrode was used to identify functional neural tissue before undertaking microsurgical dissection in 58 individuals (95%). In the majority of these patients, evoked EMG activity occurred either in one (33%) or in two muscles (9%) simultaneously. The presence of electrically evoked EMG activity in structures encountered during microdissection altered the plan of treatment in 24 cases (42%). CONCLUSIONS: The authors conclude that the combined SSEP and EMG monitoring of lower-limb muscles, EAS, and EUS is a practical and reliable method for obtaining optimal electrophysiological feedback during complex neurosurgical procedures involving the conus medullaris and cauda equina. Analysis of the results indicates that these intraoperative adjunctive modalities positively influence decision making with regard to microsurgery and reduce the risk of perioperative neurological complications. Validation of the clinical value of these approaches, however, will require further assessment in a larger prospective cohort of patients.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle