Notice bibliographique
Résumé
Clinical practice guidelines have traditionally recommended manual blood pressure (BP) measurement in the office setting as the standard method for diagnosing hypertension. In reality, manual BP in routine clinical practice is relatively inaccurate, over-diagnoses hypertension by provoking office-induced increases in BP and correlates poorly with both the awake ambulatory BP and target organ damage. The most recent guidelines recommend 24-h ambulatory BP and home BP for diagnosing hypertension. The advent of automated office BP (AOBP) represents a third alternative to conventional manual BP measurement, one that maintains the role of office BP readings in the diagnosis and management of hypertension. AOBP has three basic principles: multiple readings taken using a fully automated sphygmomanometer with the patient resting quietly alone. AOBP eliminates office-induced hypertension such that the cut-point for a normal AOBP is the same as for the awake ambulatory BP and home BP. As compared to routine manual office BP, AOBP provides more accurate BP readings, is more consistent during repeated office visits and in different settings and correlates better with both the awake ambulatory BP and target organ damage. The advantages of AOBP over manual BP measurement support its use in routine clinical practice.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,004 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».