Heat Transfer Through Metal-Foam Heat Exchanger at Higher Temperature
Notice bibliographique
Résumé
Open pore metal foams are lightweight and offer high strength, rigidity, and a large heat transfer area per volume. They make efficient heat exchangers because of high thermal conductivity and high permeability. These heat exchangers made of nickel foam are suitable for high temperature application. They can be manufactured by shaping the foam into any desired configuration and depositing metal skins on it using thermal spray deposition method. Combustion based heating system that burns natural gas is designed to understand the heat transfer through metal foam heat exchanger at higher temperature. A test rig has been fabricated to perform heat transfer experiments. The rig is capable of generating hot combustion gases through methane-oxygen premixed combustion chamber. The design of the rig allows exposure of the thermally sprayed nickel foam to hot gases and finally, cooling the metal foam by circulating air through it. The experiments were performed on metal foam and hollow channel to measure the heat transfer enhancement of the metal foam. The surface temperature measurements were done for different flow rates of cooling air. A significant decrease in surface temperature of metal foam was observed.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,022 | 0,002 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; les deux têtes enseignantes s’accordent sur ce qui est montré ici.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».