Real-Time Continuous Intraoperative Electromyographic and Somatosensory Evoked Potential Recordings in Spinal Surgery: Correlation of Clinical and Electrophysiologic Findings in a Prospective, Consecutive Series of 213 Cases
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
In Brief Study Design. Retrospective analysis of a prospectively accrued series of 213 consecutive patients who underwent intraoperative neurophysiologic monitoring with electromyography and somatosensory-evoked potentials during thoracolumbar spine surgery. Objectives. To study the incidence of significant intraoperative electrophysiologic changes and new postoperative neurologic deficits. Summary of Background Data. Continuous intraoperative electromyography and somatosensory-evoked potentials are frequently used in spinal surgery to prevent neural injury. However, only limited data are available on the sensitivity, specificity, and predictive values of intraoperative electrophysiologic changes with regard to the occurrence of new postoperative neurologic deficits. Methods. We examined data on patients who underwent intraoperative monitoring with continuous lower limb electromyography and somatosensory-evoked potentials. The analysis focused on the correlation of intraoperative electrophysiologic changes with the development of new neurologic deficits. Results. A total of 213 patients underwent surgery on a total of 378 levels; 32.4% underwent an instrumented fusion. Significant electromyograph activation was observed in 77.5% of the patients and significant somatosensory-evoked potential changes in 6.6%. Fourteen patients (6.6%) had new postoperative neurologic symptoms. Of those, all had significant electromyograph activation, but only 4 had significant somatosensory-evoked potential changes. Intraoperative electromyograph activation had a sensitivity of 100% and a specificity of 23.7% for the detection of a new postoperative neurologic deficit. Somatosensory-evoked potentials had a sensitivity of 28.6% and specificity of 94.7%. Conclusions. Intraoperative electromyographic activation has a high sensitivity for the detection of a newpostoperative neurologic deficit but a low specificity. In contrast, somatosensory-evoked potentials have low sensitivity but high specificity. Combined intraoperative neurophysiologic monitoring with electromyography and somatosensory-evoked potentials is helpful for predicting and possibly preventing neurologic injury during thoracolumbar spine surgery. Spine 2004;29:677–684 We studied 213 patients undergoing thoracolumbar surgery and intraoperative neurophysiologic monitoring. Significant activation of electromyography occurred in 77.5%. Significant somatosensory-evoked potential changes occurred in 6.6% of the patients. The sensitivity of electromyography to detect new postoperative deficits was high, whereas specificity was low. Somatosensory-evoked potentials had low sensitivity but high specificity.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |