Infrared radiometry-based background-compensated thermometric instrument for noncontact temperature and friction measurements
Notice bibliographique
Résumé
The design and performance of a novel thermometric instrument featuring thermalemission-intensity harmonic modulation, noncontact infrared radiometric detection, and stray background suppression is described. The instrumental principle depends on thermal (blackbody) emission of Planck radiation from a heated surface. It was developed to measure small temperature rises caused by frictional heating. A low-power He–Ne heating laser was used to investigate the sensitivity and estimate a figure-of-merit (FOM) for the instrument. Background compensation leading to signal baseline suppression was partly achieved with a differential mechanical chopper blade, designed to induce destructive interference of infrared radiation superposition from heated and reference spots on a ceramic sample coated with a metallic thin film. Additional background suppression was achieved by lock-in amplifier signal amplitude and phase compensation through an externally superposed wave at the same chopping frequency. The FOM of the noncontact thermometric instrument was 159.9±8.5. The system sensitivity (minimum temperature rise) for the particular thin-film/ceramic material was estimated to be 0.18–0.23 °C.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».