Adsorption of Fibrinogen and Lysozyme on Silicon Grafted with Poly(2-methacryloyloxyethyl Phosphorylcholine) via Surface-Initiated Atom Transfer Radical Polymerization
Notice bibliographique
Résumé
Surfaces based on grafted poly(2-methacryloyloxyethyl phosphorylcholine) (poly(MPC)) "brushes" with a constant graft density of 0.39 chain/nm2 and chain length from 5 to 200 monomer units were prepared by surface-initiated atom transfer radical polymerization (ATRP) on silicon wafers. The chain length and layer thickness of the poly(MPC) grafts were varied via the ratio of MPC to sacrificial initiator. The surfaces were characterized by water contact angle, XPS, and AFM. The effect of poly(MPC) chain length on fibrinogen and lysozyme adsorption was studied in TBS buffer at pH 7.4. The adsorption of both proteins on the poly(MPC)-grafted surfaces was greatly reduced compared to the unmodified silicon. Adsorption decreased with increasing chain length of the poly(MPC) grafts. Grafts of chain length 200 (MW 59 000) gave adsorption levels of 7 and 2 ng/cm2, respectively, for fibrinogen and lysozyme at 1 mg/mL protein concentration, corresponding to reductions of greater than 98% compared to the unmodified silicon. Adsorption experiments using mixtures of the two proteins showed that the suppression of protein adsorption on the poly(MPC)-grafted surfaces was not strongly dependent on protein size or charge.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».