Calibration of thermal conductivity sensors with consideration of hysteresis
Notice bibliographique
Résumé
A thermal conductivity sensor monitors soil suction by measuring the changes in thermal conductivity of the porous tip. The thermal conductivity of the porous tip is a direct function of its water content. It has long been recognized that the suction versus water content relationship of a porous material exhibits hysteresis of various magnitudes between wetting and drying processes. The sensor output may correspond to various suction values of the sensor porous tip, depending on the wetting or drying state of the porous tip. The current calibration procedure, however, represents only one of the drying processes of the sensor porous tip. A laboratory testing program was carried out to better understand the hysteretic properties of the sensor output voltage versus the suction and to further improve the calibration procedure. The output of the sensor was monitored as the sensor porous tip was subjected to various drying and wetting processes. The test results indicate an error of 30%70% for suctions higher than 100 kPa if the hysteretic effects of the porous tip are not considered in data interpretation. Based on the laboratory testing results, a revised calibration procedure was proposed that takes into consideration the capillary hysteretic effects.Key words: thermal conductivity sensor, calibration, matric suction, capillary hysteresis.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».