Effect of Gap Distance on Confined Boiling Heat Transfer Over a Saturated Porous Structure
Notice bibliographique
Résumé
An experimental investigation was performed to study the effect that the introduction of a gap between a heated fin and a porous media would have on the heat removal characteristics of a capillary evaporator. In these experiments, a thin stainless steel resistive foil stretched between two copper electrodes was used to heat a saturated porous plate with an effective pore size of 50 microns. The temperature distribution on a 10 mm wide simulated fin was measured by a high-speed infra-red thermal imaging system. The heat removal performance was investigated for gap distances of 0.00 to 1.00 mm and for heat fluxes of 17 to 180 kW/m2. These results showed that the maximum heat transfer rate that could be achieved before persistent hot spots were observed on the surface increased with gap distance. Local temperature measurements made using thermocouples embedded in the porous media indicate that vapour penetration into the porous wick is intermittent, and that there is no stable single phase blanket of vapour. For a gap distance of 0.00 mm, this penetration is more uniformly distributed across the width of the heated fin than at a gap distance of 0.50 mm. In the latter case, the vapour distribution is much higher near the edge of the heated fin.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».