Dynamic calibration of tri-axial piezoelectric force transducers
Notice bibliographique
Résumé
Applied dynamic loads are often difficult to measure accurately due to the dynamic response of the sensor used and the dependence of the sensor's sensitivity on the mounting and loading details. For tri-axial force transducers, which are capable of measuring forces along the axial direction and along both directions of the transducer's face, dynamic calibration is further complicated by the coupling of the sensor's measurement directions. For this reason, a new apparatus for dynamic calibration of normal and tangential directions of a tri-axial piezoelectric force transducer has been constructed and tested. The calibration force is provided from a spring loaded uni-axial impulse hammer. The apparatus allows for calibration at a variety of calibration angles and speeds; the loading for all cases of a nonzero calibration angle is oblique, with the point of force application being eccentric to the centerline of the force transducer's normal axis. As such, tangential loads are always accompanied by a normal load. The calibration results show that the normal direction correction factors have a systematic dependence on the calibration angle; the tangential correction factors show some scatter but do not appear to be dependent on the calibration angle.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».