Randomized, Prospective Study of Low-Dose Versus High-Dose Inhaled Nitric Oxide in the Neonate With Hypoxic Respiratory Failure
Notice bibliographique
Résumé
OBJECTIVE: There is little information on the response to very low doses of inhaled nitric oxide (iNO) in hypoxic near-term infants. The potential toxicities of iNO are dose related; thus, the ability to use lower doses safely and effectively may be advantageous. We hypothesized that there is no difference in the acute improvement in oxygenation between treatment with inhaled nitric oxide at 1 to 2 parts per million (ppm) or 10 to 20 ppm. METHODS: We randomized near-term and term infants with hypoxic respiratory failure with oxygenation indices (OIs) of >/=10 and PaO(2) <100 on 2 separate blood gases taken at least 30 minutes apart. Infants with congenital diaphragmatic hernia were excluded. After parental consent was obtained, patients were randomized to receive a starting nitric oxide (iNO) dose of either 1 to 2 ppm (low-dose group, n = 15) or 10 to 20 ppm (high-dose group, n = 21). The response to iNO was assessed according to the increase in arterial PaO(2) and decrease in OI 30 to 60 minutes after exposure to the initial starting concentration. A response of <10% increase on PaO(2) and a <10% decrease in OI resulted in a doubling of iNO within the dose range protocol (1, 2, 4, and 8 ppm for the low-dose group; 10, 20, 40, and 80 ppm for the high-dose group). RESULTS: Thirty minutes after the study gas was initiated, PaO(2) increased significantly overall in the low-dose (90.7 +/- 41 torr to 166.8 +/- 95.6 torr) and high-dose (76.2 +/- 32.7 torr to 198.7 +/- 142.8 torr) groups; the maximal increase was seen in the infants who initially were treated with 10 ppm. The OI also decreased significantly overall and also was significant in the high-dose group (21.0 +/- 13.7 to 11.4 +/- 10.4; low-dose: 18.3 +/- 7.1 to 13.2 +/- 12.3). There was a nonsignificant fall of PaCO(2) with iNO treatment (low dose 35 +/- 7.3 to 30 +/- 8.5 torr vs high dose 35.2 +/- 9.9 to 32.4 +/- 10.7 torr). A sustained response (ie, maintaining a PaO(2) and OI gain greater than 20% for the duration of the study gas administration) was greater in the high-dose group (53.3% vs 30.0%). In addition, dose increases were required more often in the low-dose group than in the high-dose group (80.0% vs 57.1%). Among patients who did not respond to the initial iNO dose, 100.0% and 83.3% responded at higher doses of iNO for the low- and high-dose groups, respectively. There were no differences for death, need for extracorporeal membrane oxygenation, or other outcomes between the groups. CONCLUSIONS: We did not find any significant difference in response to low- versus high-dose iNO. An initial exposure to low-dose iNO does not compromise the response to higher doses if required and may result in less toxicity.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,005 | 0,007 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,004 | 0,002 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,002 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,003 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,005 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».