Submillimeter accuracy in radiosurgery is not possible

2013· article· en· W2039985219 sur OpenAlexaboutno aff
T Bichay, Sonja Dieterich, Colin G. Orton

Notice bibliographique

RevueMedical Physics · 2013
Typearticle
Langueen
DomainePhysics and Astronomy
ThématiqueAdvanced Radiotherapy Techniques
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésRadiosurgeryMedical physicistMedical physicsMedical imagingMedicineBrachytherapyDosimetryRadiation oncologyRadiation treatment planningNuclear medicineComputer scienceRadiologyRadiation therapyPhysics

Résumé

récupéré en direct d'OpenAlex

Arguing against the Proposition is Sonja Dieterich, Ph.D. After completing her Ph.D. in Nuclear Physics at Rutgers University in 2002, Dr. Dieterich received training in Medical Physics at Georgetown University Hospital, Washington, DC, from 2002 to 2003. In 2003, she accepted a faculty position at Georgetown. From 2007 to 2012, she worked at Stanford University Hospital as Clinical Associate Professor and Chief of Radiosurgery Physics. Since April 2012 she is an Associate Professor and Physics Residency Co-Director at the University of California Davis. Dr. Dieterich is Chair of the AAPM Task Group 135 "QA for Robotic Radiosurgery" and a member of the ASTRO Physics and Multi-Disciplinary QA Committees. Her current research interests are the development of QA/QM programs for new technologies, image-guided brachytherapy, and Veterinary Radiation Oncology. The advent of cranial radiosurgical therapy has allowed a nonsurgical approach to the treatment of cranial lesions.1 The obvious benefits apply to both malignant as well as benign lesions. Historically a rigid invasive frame, attached to the patient's skull via small screws, acted as both immobilizer and localizer. With such devices, the frame defines a 3D coordinate system within which the skull and targeted lesion are intended to remain fixed from the time of the planning CT scan to the completion of treatment. More modern radiosurgical systems may use 3D "image-guided" positioning for exact alignment. Accuracy of radiosurgery has often been considered as ultimately relying on the rigidity of the immobilizer, as opposed to the treatment system as a whole. This ignores multiple other factors that must also be included. Typical quoted values for frame-based immobilization accuracy are 0.3–0.6 mm.2–4 This measure relates only to flex between the frame and the skull, and the stability of the treatment apparatus. The system accuracy as a whole must also include end-to-end uncertainties that result from the spatial resolution of the original CT, resolution and linearity of the MRI scan, contouring uncertainty, treatment planning grid resolution, algorithm errors, CT to MRI registration uncertainty, etc. The now-dated AAPM report 54 (Ref. 5) suggested that the total uncertainty can reach 2–3 mm. The planning system is designed to calculate an optimized dose distribution around a physician-determined region of interest (ROI). Since the physician-drawn ROI is a function of the window and level differences on CT and MRI, there is variability between physicians, which even for well-identified normal structures (let alone often less distinct targets) can exceed 1–2 mm.6 A recent study by a Canadian group demonstrated a shift in tumor isocenter of 1.4 mm by simply altering the time of CT imaging after injected contrast.7 An analysis of the registration accuracy of CT with MRI for several algorithms determined typical errors along the x, y, and z axes of approximately 0.68, 1.04, and 0.60 mm, respectively. When added in quadrature this amounts to a vector of 1.4 mm.8 Others have published even greater variability.9 A recent Gamma Knife end-to-end study, evaluating the distance to agreement, determined that the uncertainty was better than expected based on quadrature-sum but still over 1 mm.10 The planning system dose grid is unlikely to have a resolution of less than 1 mm and the dose calculation algorithm will itself contain some uncertainty in placement of dose within the grid due to imperfect modeling of radiation transport. Since a significant percent of target definition is done on MRI datasets it is important to note that even for MRI systems compliant with ACR guidelines, the distortion can reach up to 2 mm.11 Taking all of the above uncertainties into account is essential in deriving a realistic overall accuracy for SRS treatment. It is apparent that radiosurgery treatment using current technology and considering human factors, when observed from end-to-end, cannot reach submillimeter accuracy. The crux of this debate is the definition of "Accuracy in Radiosurgery." In the literature, there is significant confusion caused by imprecise language. If we are debating the mechanical accuracy of the delivery system to align to isocenter, the answer is straightforward and supported by literature. Current mechanical engineering techniques meet this standard easily.3,12,13 Frameless, image-guided radiosurgery adds the requirement to match the imaging isocenter to the mechanical isocenter. A look at the QA tables contained in TG-142 confirms that the expert authors consider this an achievable goal for standard QA.14 The next level of achieving submillimeter accuracy is to match the radiation isocenter to the mechanical isocenter using image-guidance. This task can be achieved by, for example, using an end-to-end (E2E) test. A literature search confirms submillimeter accuracy in E2E tests is achievable on CyberKnife,3 Truebeam,15 and Gamma Knife13 machines. We should assume similar E2E accuracy for other delivery systems (to be published soon). Radiosurgery targets are not always spherical or elliptical. Patient-specific delivery QA (DQA) is done to assess how mechanical, imaging, treatment planning, and radiation isocenter uncertainties combine in a rigid phantom. In IMRT, gamma criteria of 3%/3 mm are customarily used. To argue my case, I must argue that a reduction to 3%/1 mm is possible.15 This is the point where the argument becomes too complex to support a binary answer to our hypothesis. First, the 1 mm criterion. Everyone who has performed a DQA is aware that working on an accuracy scale of 1 mm is a very time-intensive undertaking. The two QA devices we have available to reach this resolution are film and gels. Other QA devices have been shown to be unable to detect mechanical shifts of 1 mm in delivery.16 Therefore, we cannot use them to verify that a radiosurgery device is accurate to <1 mm. What about the 3% dose uncertainty: does it belong in this argument? I could choose the easy way out and argue that we are mixing units, hence it should be excluded. But as I like to point out, any uncertainty in dose, may it originate from dose calculation algorithms, delivery uncertainties, or any other possible cause, is equivalent to moving an isodose line. Up to this point, we have been working in the physics realm of phantom testing for which we have confirmation of our ability to achieve submillimeter accuracy, so this proves the Proposition to be invalid. Once we step out of the phantom world and apply radiosurgery to patients, I have to concede. Even in as seemingly simple a task as contouring, we are still limited by imaging, causing contouring uncertainties of several millimeters among expert physicians. Not to mention residual patient motion or changes in internal anatomy. Since this is a physics publication, I am going to claim these factors are beyond this discussion, and still claim to have disproved the Proposition. What an interesting approach to this debate. My esteemed colleague initially claims that 1 mm accuracy is achievable, then executes an elegant demi-tour and concedes that it cannot be met, only to follow with another demi-tour, discounting any parameters that are inconvenient, and claims victory! I applaud Dr. Dieterich's breakdown of the components of radiosurgery. My colleague states that, when these parameters are applied to a phantom, using certain specialized tools, assuming that a 3% dose error is nonexistent, ignoring contouring uncertainties, ignoring organ motion, ignoring imaging uncertainties, etc. we can achieve 1 mm accuracy! The reasoning is that this is a medical physics publication; hence clinical realities that affect accuracy can be excluded from the equation. Not so I say! After all, as medical physicists we can hardly modify the accuracy of our linear accelerator's isocenter. This is determined by a vendor over which we have little control. The accuracy of our imaging system, our treatment planning system, registration software, etc. are also predetermined for us. We can measure their accuracy, but cannot modify them. Similarly, we can measure the clinical uncertainties that exist, from one clinician to another in contouring, for example, or how windowing levels affect contouring, or organ motion during respiration. We can measure those parameters but not affect them. They are still part of the equation. This reality of accuracy should hold whether the debate takes place in Medical Physics or in the International Journal of Radiation Oncology, Biology, Physics. Because physicists concentrate largely on parameters that are within their control and can be readily applied to a phantom, such as physical or dosimetric measurements, we sometimes forget, or choose to ignore, the big picture. Our physician colleagues hear us tell them that our treatments are accurate within a certain tolerance, and they believe us. We need to step back and look at the reality from a larger perspective that includes all relevant parameters. The weakest links, be they imaging, mechanical, dosimetric, or clinical, must be identified and addressed. When we do take these parameters into consideration, submillimeter accuracy in a patient is currently not achievable. Dr. Bichay states: "It is apparent that radiosurgery treatment using current technology and considering human factors, when observed from end-to-end, cannot reach sub-millimeter accuracy." This is in direct contradiction to peer-reviewed papers3,15,17–19 demonstrating submillimeter accuracy with end-to-end tests for several radiosurgery methods. Furthermore, he is offering no supporting literature for his statement that the planning system dose grids are unlikely to have dose grid resolutions of less than 1 mm. Modern treatment planning systems have dose grid resolutions matching (Accuray MultiPlan) or exceeding20 the voxel resolution of the CT image. At 512 × 512 with a field of view of 250 mm for a cranial scan, this is equivalent to 0.5 mm. The interpolation between dose points pushes the resolution even higher, because for photon treatments dose gradients are relatively smooth. It is also no longer true that a significant percentage of target definition is done on MR data sets alone. The fraction of radiosurgery patients with plans generated on MR-based planning systems has been declining; more widely used modalities such as linac based SRS use CT based treatment planning, with MR being used as an additional, complementary component of the contouring process. Even where MR is used for target definition (but not for localization), the 2 mm MR distortion Dr. Bichay references is measured over the extent of the MR phantom (>100 mm). Over the typical diameter of a large brain metastasis, 20– 30 mm, the expected distortion is less than 0.5 mm. I do agree with Dr. Bichay that there is significant variability in defining the target volume. Quantitative imaging of disease has not reached the quality or resolution needed to achieve submillimeter accuracy. While I disagree with Dr. Bichay when I maintain that we can achieve submillimeter accuracy spatially and most likely dosimetrically (at least for rigid targets in homogeneous areas of the body), I do agree with him that submillimeter accuracy in contouring is as yet beyond our reach.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,018
score de la tête « metaresearch » (Gemma)0,038
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Théorique ou conceptuel · Signal consensuel: Théorique ou conceptuel
GenreSignal candidat: Empirique · Signal consensuel: aucune
Score de désaccord entre enseignants0,018
Score d'incertitude au seuil0,096

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0180,038
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0010,001
Études des sciences et des technologies0,0020,013
Communication savante0,0040,010
Science ouverte0,0030,006
Intégrité de la recherche0,0060,011
Charge utile insuffisante (le modèle a refusé de juger)0,0060,005

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,014
Tête enseignante GPT0,283
Écart entre enseignants0,269 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeThéorique ou conceptuel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations10
Publié2013
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueMedical PhysicsMême sujetAdvanced Radiotherapy TechniquesTravaux en français237 207