Registration of two‐dimensional cardiac images to preprocedural three‐dimensional images for interventional applications
Notice bibliographique
Résumé
PURPOSE: To evaluate the accuracy and efficiency of rigid-body registration of two-dimensional fast cine and real-time cardiac images to high-resolution and SNR three-dimensional preprocedural reference volumes for application during MRI-guided interventional procedures. MATERIALS AND METHODS: Mutual information (MI) and correlation ratio (CR) similarity measures were evaluated. The dependence of registration accuracy and efficiency on different resolution and SNR parameters, and also on cardiac-phase differences was evaluated in a porcine model. Two-dimensional images were initially misoriented at distances (d) of 2-10 mm, and rotations of +/-5 degrees about all axes. Registration error and computation time were evaluated, and performance was also assessed visually. RESULTS: The maximum registration error using MI (<2.7 mm and <3.6 degrees ) occurred for d = 10 mm, misrotation of +/-5 degrees , and relative SNR = 1. The computation time was 15 seconds for MI and 10 seconds for CR. CONCLUSION: Registration accuracy was not highly dependent on the relative timing, within the cycle, between the two-dimensional and three-dimensional images. Registration using CR was faster than that using MI, although accuracy was marginally higher with MI. J.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,007 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».