Assessment of Closing Pressure in Silicone Ahmed FP7 Glaucoma Valves
Notice bibliographique
Résumé
PURPOSE: To measure closing pressure in a series of new Model FP7 silicone Ahmed Glaucoma Valves (AGVs), using an in vitro gravity-driven system, in which closing pressure was measured directly from a dual manometer/pressure reservoir. METHOD: A straight length of tubing served as an open manometer, which connected via a 3-way stopcock to the inlet of the AGV submerged under 1.5 cm of balanced saline solution (BSS). Six AGV were assessed in 5 sequential trials and the mean inlet pressure at 90 minutes was recorded as the closing pressure. After testing, a single valve was primed a second time using greater force and retested. Control trials were performed with a submerged 26-G cannula opening directly into the BSS bath. RESULTS: At 90 minutes, the 6 valves equilibrated at a mean inlet pressure of 7.1 mm Hg, with a range from 1.4 to 13.5 mm Hg. Closing pressures at or less than 5 mm Hg were measured in half (3/6) of the valves tested. The average flow of BSS across the valves in the final 30 minutes was less than 1.5x10(-2) microL/min. In the single valve reperfused under greater pressure, the closing pressure increased. CONCLUSIONS: Model FP7 AGVs, in vitro, exhibit significant variability in closing pressure, with half closing at intraocular pressures considered potentially problematic in clinical situations. The results of the high-pressure perfusion experiment suggest that more research into the priming process is required so a precise description can be developed for surgeons.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».