Transmission and fluorescence angular domain optical projection tomography of turbid media
Notice bibliographique
Résumé
When imaging through turbid media, objects are often blurred by scattered light. An optical collimator (i.e., an angular filter array) improves images by accepting only photons propagating within a narrow solid angle about the direction of the incident light. These photons are expected to participate in a limited number of small-angle scattering events, maintaining their original propagation direction and, finally, contributing to the development of a faithful image of an object within a turbid medium. The collimation method, also referred to as angular domain imaging (ADI), applies to a see-through configuration where the incident collimated light beam can be aligned with the collimator in a transillumination mode of operation. In this paper, we present angular domain optical projection tomography (ADOPT), a method that can extract depth information of optical contrast in turbid media with high longitudinal resolution based on ADI technology. The resolution of the ADI system has been tested over various depths in a 5 cm optical cuvette using a resolution target suspended in a homogeneous turbid medium. The ADOPT system reconstructed images from a series of angular domain projections collected at angular intervals. The system was used to measure the attenuation of an absorbing target in transmission mode (t-ADOPT) and to measure the light emitting from a fluorescent target (f-ADOPT). Tissue-mimicking phantoms were used to validate the performance of the method. In the t-ADOPT configuration, a background scattered light estimation and subtraction methodology was introduced to improve the imaging contrast. A target consisting of two graphite rods (0.9 mm diameter) was suspended in the cuvette by a rotation stage. An Indocyanine Green-filled glass rod was used as an imaging target in the f-ADOPT arrangement. The target was placed in a manner such that the line of laser light was perpendicular to the longitudinal axis of the rods. Several projections were collected at increments of 1.8 degrees and compiled into a sinogram. A transverse image was reconstructed from the sinogram by using filtered backprojection and image contrast was improved by experimental scatter measurements using a wedge prism and an image processing algorithm. The submillimeter target embedded in a 2 cm thick scattering medium (reduced scattering coefficient < or = 2.4 cm(-1)) was discernable in both the sinograms and the reconstructed images. In the f-ADOPT system, fluorescent line targets <1 cm in diameter embedded in a 2 cm thick scattering medium (reduced scattering coefficient < or = 0.8 cm(-1)) were discernable in both the sinograms and the reconstructed images. The proposed method could be used as the basis to construct an optical tomographic scanner for simultaneous absorption and fluorescence-based imaging of biological specimens (i.e., up to 7 mm across).
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».