Improved interdigital sensors for structural health monitoring of composite retrofit systems
Notice bibliographique
Résumé
In this article, an improved sensor performance based on detecting the dielectric variations in composite—concrete interface and linking these variations to bond deterioration is presented. The use of composites in retrofitting concrete structures is becoming a standard technique worldwide. The bond between the composite system and the concrete element surface is essential to ensure achieving the designed performance. However, there is little research on the development of an economic structural health monitoring technique for monitoring bond quality in large structures, such as buildings and bridges. The improved sensing technique utilizes an Interdigital Capacitance Sensor design to increase the signal-to-noise ratio and to detect shallow—depth bond deteriorations. An analytical modeling technique was used to analyze the influence of the different sensor parameters, especially the dependency of the capacitance signals on the sensor geometrical dimensions. Two-dimensional finite element (FE) simulations were also used to assess different related design parameters and to verify the experimental results. A concrete slab retrofitted with composites containing pre-induced air voids to simulate bond deteriorations defects were constructed and inspected in a laboratory setting. Good agreements were found between experimental capacitance signal response parameters and those predicated from the FE simulations of the slab specimen.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».