Calibration of the osmotic technique of controlling suction with respect to temperature using a miniature tensiometer
Notice bibliographique
Résumé
The osmotic technique was calibrated at various temperatures (20–40 °C) using a high-capacity tensiometer. The effect of temperature on the calibration curve of the high-capacity tensiometer in the positive range has been found to be insignificant, i.e., about 0.03%/°C. The measurement at ambient temperature shows that the suction value is not significantly dependent either on the molar mass of polyethylene glycol (PEG) or on the molecular weight cutoff (MWCO) of the semipermeable cellulose membrane. On the other hand, the matric suction measured in the present work by tensiometer was lower than the total suction found in the literature measured by psychrometer. This shows that the so-called membrane effects must be characterized by not only the crossing of PEG molecules but also other complex phenomena. The calibration at controlled temperatures showed a slight suction decrease of 1%/°C. One possible explanation for this decrease is that increasing the temperature decreases the viscosity of PEG solutions, possibly accelerating the crossing of PEG molecules. It is also possible that increasing the temperature changes the physicochemical properties of the PEG solutions, resulting in a suction decrease.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».