Free Breathing Real-Time Cardiac Cine Imaging With Improved Spatial Resolution at 3 T
Notice bibliographique
Résumé
OBJECTIVES: The aim of this study was to evaluate free-breathing single-shot real-time cine imaging for functional cardiac imaging at 3 T with increased spatial resolution. Special emphasis of this study was placed on the influence of parallel imaging techniques. MATERIALS AND METHODS: Gradient echo phantom images were acquired with GRAPPA and modified SENSE reconstruction using both integrated and separate reference scans as well as TGRAPPA and TSENSE. In vivo measurements were performed for GRAPPA reconstruction with an integrated and a separate reference scan, as well as TGRAPPA using balanced steady-state free precession protocols. Three clinical protocols, rtLRInt (Tres = 51.3 milliseconds; voxel, 2.5 × 5.0 × 10 mm³), rtMRSep (Tres = 48.8 milliseconds; voxel, 1.9 × 3.1 × 10 mm³), and rtHRSep (Tres = 48.3 milliseconds; voxel, 1.6 × 2.6 × 10 mm), were investigated on 20 volunteers using GRAPPA reconstruction with internal as well as separate reference scans. End-diastolic volume, end-systolic volume, ejection fraction, peak ejection rate, peak filling rate, and myocardial mass were evaluated for the left ventricle and compared with an electrocardiogram-triggered segmented readout cine protocol used as standard of reference. All studies were performed at 3 T. RESULTS: Phantom and in vivo data demonstrate that the combination of GRAPPA reconstruction with a separate reference scan provides an optimal compromise of image quality as well as spatial and temporal resolution. Functional values (P values) for the standard of reference, rtLRInt, rtMRSep, and rtHRSep end-diastolic volume were 141 ± 24 mL, 138 ± 21 mL, 138 ± 19 mL, and 128 ± 33 mL, respectively (P = 0.7, 0.7, 0.4); end-systolic volume, 55 ± 15 mL, 61 ± 14 mL, 58 ± 12 mL, and 55 ± 20 mL, respectively (P = 0.23, 0.43, 0.62); ejection fraction, 61% ± 5%, 57% ± 5%, 58% ± 4%, and 56% ± 8%, respectively (P = 0.01, 0.11, 0.06); peak ejection rate, 481 ± 73 mL/s, 425 ± 62 mL/s, 434 ± 67 mL/s, and 381 ± 86 mL/s, respectively (P = 0.03, 0.04, 0.01); peak filling rate, 555 ± 80 mL/s, 480 ± 70 mL/s, 500 ± 70 mL/s, and 438 ± 108 mL/s, respectively (P= 0.007, 0.05, 0.004); and myocardial mass, 137 ± 26 g, 141 ± 25 g, 141 ± 23 g, and 130 ± 31 g, respectively (P = 0.62, 0.54, 0.99). CONCLUSIONS: Using a separate reference scan and high acceleration factors up to R = 6, single-shot real-time cardiac imaging offers adequate temporal and spatial resolution for accurate assessment of global left ventricular function in free breathing with short examination times.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,001 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».