Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
BACKGROUND: Standard noninvasive impedance cardiography has been used to examine the cardiovascular responses of individuals to a wide range of stimuli in critical care and laboratory settings. It has been shown to be a reliable alternative to invasive thermodilution techniques and an acceptable alternative to the use of a pulmonary artery catheter. Ambulatory impedance cardiography provides a similar assessment of cardiac function to standard noninvasive impedance cardiography, but it does so while individuals engage in activities of daily living. It offers portability and the option of managing complex patients in outpatient settings. OBJECTIVE: To critically examine through a literature analysis the validity, reliability, and sensitivity of ambulatory impedance cardiography for the assessment of cardiac performance during activities of daily living. METHODS: The Cochrane Database of Systematic Reviews (CDSR), The Cochrane Database of Methodology Reviews (CDMR), The Cochrane Central Register of Controlled Trials (CENTRAL), Database of Abstracts of Reviews of Effects (DARE), National Health Service Economic Evaluation Database (NHS EED), Health Technology Assessment (HTA), and The Cochrane Methodology Register (CMR; 1966-2005); MEDLINE (1950-2005); and CINAHL (1982-2005) were searched using the following terms: ambulatory cardiac performance, impedance cardiac performance, AIM cardiac performance monitor, thoracic electrical bio-impedance, impedance cardiography, ambulatory impedance monitor, bio-impedance technology, ambulatory impedance cardiography, bio-electric impedance; also included were reference lists of retrieved articles. Studies were selected if they used an ambulatory impedance monitor to examine one or more of the following cardiovascular responses: pre-ejection period (PEP), left ventricular ejection time (LVET), stroke volume (SV), or a combination of these. RESULTS: Studies have been predominantly descriptive and have been focused on a young, male population with a normal body mass index (BMI; 25-29 kg/m). Inconsistencies in determining specific markers of cardiac function (e.g., PEP and SV) across studies necessitated that results be reported by outcome for each study separately. DISCUSSION: Ambulatory impedance monitors are valid and reliable instruments used for the physiologic measurement of cardiac performance. Sensitivity is established utilizing within-individual measurements of relative change. This is especially important in light of an aging population and technical advances in healthcare. Further research is warranted using nursing interventions that focus on an older, female population who have a BMI greater than 30 kg/m. Availability of noninvasive ambulatory measures of cardiac function has the potential to improve care for a variety of patient populations, including those with hypertension, heart failure, pain, anxiety, and depressive symptoms.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,002 | 0,001 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle