Development of a Novel Immunoradiometric Assay Exclusively for Biologically Active Whole Parathyroid Hormone 1–84: Implications for Improvement of Accurate Assessment of Parathyroid Function
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
We developed a novel immunoradiometric assay (IRMA; whole parathyroid hormone [PTH] IRMA) for PTH, which specifically measures biologically active whole PTH(1-84). The assay is based on a solid phase coated with anti-PTH(39-84) antibody, a tracer of 125I-labeled antibody with a unique specificity to the first N-terminal amino acid of PTH(1-84), and calibrators of diluted synthetic PTH(1-84). In contrast to the Nichols intact PTH IRMA, this new assay does not detect PTH(7-84) fragments and only detects one immunoreactive peak in chromatographically fractionated patient samples. The assay was shown to have an analytical sensitivity of 1.0 pg/ml with a linear measurement range up to 2,300 pg/ml. With this assay, we further identified that the previously described non-(1-84)PTH fragments are aminoterminally truncated with similar hydrophobicity as PTH(7-84), and these PTH fragments are present not only in patients with secondary hyperparathyroidism (2 degrees -HPT) of uremia, but also in patients with primary hyperparathyroidism (1 degrees -HPT) and normal persons. The plasma normal range of the whole PTH(1-84) was 7-36 pg/ml (mean +/- SD: 22.7 +/- 7.2 pg/ml, n = 135), whereas over 93.9% (155/165) of patients with 1 degrees -HPT had whole PTH(1-84) values above the normal cut-off. The percentage of biologically active whole PTH(1-84) (pB%) in the pool of total immunoreactive "intact" PTH is higher in the normal population (median: 67.3%; SD: 15.8%; n = 56) than in uremic patients (median:53.8%; SD: 15.5%; n = 318; p < 0.001), although the whole PTH(1-84) values from uremic patients displayed a more significant heterogeneous distribution when compared with that of 1 degrees -HPT patients and normals. Moreover, the pB% displayed a nearly Gaussian distribution pattern from 20% to over 90% in patients with either 1 degrees-HPT or uremia. The specificity of this newly developed whole PTH(1-84) IRMA is the assurance, for the first time, of being able to measure only the biologically active whole PTH(1-84) without cross-reaction to the high concentrations of the aminoterminally truncated PTH fragments found in both normal subjects and patients. Because of the significant variations of pB% in patients, it is necessary to use the whole PTH assay to determine biologically active PTH levels clinically and, thus, to avoid overestimating the concentration of the true biologically active hormone. This new assay could provide a more meaningful standardization of future PTH measurements with improved accuracy in the clinical assessment of parathyroid function.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle