Getting Smarter and Hotter With ESPs for SAGD
Notice bibliographique
Résumé
Abstract This paper summarizes the results from a high-temperature test program completed in late 2009 and discusses a new electric submersible pumping (ESP) configuration that was validated by ConocoPhillips for operations at 250°C and planned for 2010 field trials. This new prototype ESP system was jointly tested by ConocoPhillips and Schlumberger for 42 days in the C-FER Technologies high-temperature flow loop at fluid temperatures ranging from 150°C to 260°C, and at 250°C and above for approximately 40% of the total time. While the primary objective of this test program was to validate this ESP system for use in 250°C fluid temperatures, the additional instrumentation at the test facility also offered an opportunity to investigate the temperature dynamics of the fluid flowing past the motor, and the pressure and temperature behavior of the motor. The test data was also compared to data from a similar test completed in 2008 and the evaluation provided some interesting observations, which will be discussed. The information in this paper will be of value to any operator that has ESPs installed in high-temperature applications. In addition, the lessons learned from this test program may also be used to increase ESP reliability in conventional applications.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».