Method for Individual Control of Multiplexed Droplet Generation in Digital Microfluidic Devices
Notice bibliographique
Résumé
This investigation presents two methods for multiplexed droplet generation in digital microfluidic devices. Analytical and experimental results show that the number of electrical output signals required for multiple reagent systems can be reduced by electrically connecting all but one electrode in each droplet generation path on the device. Both methods reduce the number of electrical signals required for generating droplets from multiple reservoirs by M(N−1), where M is the number of manipulation electrodes in the generation path and N is the number of reservoirs on the device. The first method uses individually controlled reservoirs to minimize the manipulation of the fluid in the unused reservoir, while the second method individually controls one of the electrodes in the generation pathway to allow for closed loop control of droplet generation. In both cases, droplets are kept at rest by simultaneously activating or deactivating all adjacent electrodes. These methods can be easily integrated into devices with multiple reservoirs without computational expense or prior knowledge of the electrode activation sequence. They can also be used in concert with droplet control algorithms for pin constrained systems to further reduce the number of output channels required in a digital microfluidic device.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».