A passive mode-locked InAs/InP quantum dot laser with pulse duration of less than 300 fs
Notice bibliographique
Résumé
We have designed and fabricated a quantum dot (QD) gain medium which consists of InAs QDs in an InGaAsP matrix on an InP substrate. By using these InAs/InP QD layers, we have generated femtosecond (fs) pulses with pulse duration of 295 fs from a single-section monolithic Fabry-Perot (F-P) cavity at the repetition rate of 50 GHz around 1560 nm wavelength range without any external pulse compression. The average output power is 40.1 mW at the injection current of 200 mA. Optical signal-to-noise ratio (OSNR) of the proposed QD mode-locked laser (QD-MLL) is up to 50 dB. The lasing threshold current and the external differential quantum efficiency are 23 mA and 30 %, respectively. And the mode beating linewidth was measured to be less than 20 KHz. We have interpreted that several nonlinear optical effects related to interaction of QD excitons with intracavity laser fields could create nonlinear dispersion to compensate intracavity linear dispersion. So total dispersion is minimized and four-wave mixing (FWM) is dramatically enhanced within QD F-P cavity. If spectral bandwidth is broad enough, tens or hundreds of longitudinal modes would lase and their phases would be locked together through FWM process. Eventually a train of fs pulses with a repetition rate corresponding to cavity round-trip time is generated.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».