Proton Affinities of Simple Amines; Entropies and Enthalpies of Activation and Their Effect on the Kinetic Method for Evaluating Proton Affinities
Notice bibliographique
Résumé
The competing unimolecular dissociations of a variety of proton-bound pairs of amino compounds of formula R 1 NH 2, R 1 R 2 NH, where R 1 and R 2 are chiefly alkyl groups C 1 to C 9, have been investigated by tandem mass spectrometry. Metastable and collision-induced dissociations were studied. The relative product yields, [B 1 H + ]/[B 2 H + ], from B 1 H + B 2 ions (B n = amine) have been related to the proton affinities (PA) of B 1 and B 2 by the kinetic method. In its simplest form, the method assumes no entropy effects and a zero reverse energy barrier for the competing dissociations. The general effects expected from nonzero entropies of activation are described in terms of how they influence log(rate constant) vs internal energy plots for such competing dissociations. For these homologous series such effects were observed to be minimal and the kinetic method well reproduces most of the reference PA values. In view of the very close agreement between many reference PA values obtained from equilibrium studies, it is possible that small reverse energy barriers (ca. 5 kJ mol -1 ) may be identifiable by the kinetic method, in particular for t -C 4 H 9 NH 2, the homologous di- n -alkylamines, and possibly larger barriers for di- sec -alkylamines. The method is quite sensitive to small discrepancies in PA, and new values have been proposed for benzylamine, 924 ± 4 kJ mol -1, (CH 3 )( n -C 4 H 9 )NH, 951 ± 4 kJ mol -1, and ( i -C 4 H 9 ) 2 NH, 969 ± 4 kJ mol -1 . Results have also been obtained for some bidentate species, the 1,2-, 1,3-, and 1,4-diaminoethane, propane, and butane, respectively. Particular attention was given to the effects of activation entropies, Δ S ⧧, and the possible presence of reverse energy barriers, E rev, both of which are here a significant problem for the kinetic method. It was found that for 1,2-diaminoethane there was a Δ S ⧧ effect, particularly for collisionally activated ions. The derived PA of 949 ± 4 kJ mol -1 is quite close to the reference value for this compound, 952 ± 4 kJ mol -1 . It was concluded that for 1,3-diaminopropane (reference PA 987 ± 4 kJ mol -1 ), the method failed due both to an activation entropy effect and the presence of a reverse energy barrier. The latter was estimated to be ca. 20 kJ mol -1, making ca. 967 kJ mol -1 the apparent PA resulting from the kinetic method. For 1,4-diaminobutane (reference PA = 1006 ± 4 kJ mol -1 ), here too the kinetic method failed and similar difficulties arose with an estimated reverse energy barrier of ca. 32 kJ mol -1 . The overall results for these three compounds were compared with a recent report in this journal on low-energy collision-induced fragmentations. These results for species having a bidentate structure indicate that similar difficulties may apply to biomolecules and that PA values obtained by the kinetic method may be flawed.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».