Cause of Asphaltene Fluorescence Intensity Variation with Molecular Weight and Its Ramifications for Laser Ionization Mass Spectrometry
Notice bibliographique
Résumé
The molecular-weight (MW)-dependent fluorescence of asphaltene discovered over 20 years ago has been re-examined from a theoretical point of view. It is concluded here that the dependence is a result of the sensitivity of the jump between the non-intersecting potential energy surfaces involved in the S 1 → S 0 internal conversion to the excitation energy of the S 1 state, the energy gap, Δ E . The excitation energy of organoaromatic molecules, in general, depends upon the size of the aromatic chromophore which, in turn, has been shown to increase with the MW of the gel-permeation-chromatographic (GPC)-separated fractions of asphaltene. The larger the chromophore size, the lower the excitation energy of the S 1 state. This then leads to an increase of the vibrational Franck−Condon factor governing the rate of internal conversion where f v is the Franck−Condon factor and α is a proportionality constant. As Δ E decreases, the rate of the S 1 → S 0 transition increases in competition with the rate of fluorescence, resulting in the suppression of fluorescence with an increasing MW of the asphaltene. Thus, the vibrational Franck−Condon factor, f v, has the desirable feature that it is not directly reliant on chemical composition but only the excitation energy of the chromophore that matches the requirement for applicability to asphaltene. This recognition revealed the possibility of a critical role of IC in the laser ionization process applied in mass spectroscopy. Here, photoexcitation leads through a vertical transition to a higher lying electronic state, which, upon internal conversion to the S 1 state, S n > 1 → S 1, generates some excess vibrational energy in the S 1 state. This IC is a fast process, with k (IC) ∼ 10 13 s −1, much faster than the S 1 → S 0 IC, with k ∼ 10 6 −10 9 s −1 . However, the excess vibrational energy has a marked accelerating effect on the latter rate, which becomes an exponential function of the excess vibrational energy. With an increasing size of the aromatic chromophore (MW), Δ E decreases and the excess vibrational energy, E v, increases, and as a result, both increase the rate of k (IC) S 1 → S 0 up to a level commensurate with k (S n > 1 → S 1 ). Increased rates for k (IC) S 1 → S 0 mean an increased loss of photons and a consequently lower ion yield in the MS. The effect occurs in parallel with MW, and at a critical MW, the ion yield may drop below the detection limit. Thus, it is suggested that the extremely low value found for the MW of asphaltene in most laser ionization mass spectrometry (LIMS) experiments is due to this inherent problem in the photophysics of asphaltene. Laser photo-ionization is a complicated process that has its limitations, and its non-critical use can lead to misleading results.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».