Development of a motion‐controlled in vitro elbow testing system
Notice bibliographique
Résumé
Joint simulators can be used to study motion pathways of a human joint, to investigate changes in joint stability following injury, and to formulate improved reconstructive and rehabilitative procedures. Our objectives were: to develop a laboratory-based, motion-controlled elbow testing apparatus capable of simulating tendon (muscle) loading and displacement in a cadaveric specimen; to describe its performance while testing stable and unstable elbows; and to compare its operation to that of a previously designed load-controlled device. Velocity control of a pneumatic actuator was achieved using a custom-written, closed-loop feedback controller. This actuator was incorporated into an elbow testing system that used additional pneumatic actuators and a combination of motion- and load-control to achieve desired motions. Simulations achieved with this apparatus demonstrated small magnitudes of error in actuator position and highly repeatable flexion pathways with the specimens positioned in vertical, varus, and valgus orientations. The repeatability in motion pathways generated in both a stable and unstable elbow model was equivalent to or better than for similar tests performed using the load-controlled system, and the velocity of the resulting elbow motion was more reproducible.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,006 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».