An investigation of backscatter factors for kilovoltage x-rays: a comparison between Monte Carlo simulations and Gafchromic EBT film measurements
Notice bibliographique
Résumé
Backscatter factors are important parameters in the determination of dose for kilovoltage x-ray beams. However, backscatter factors are difficult to measure experimentally, and tabulated values are based largely on Monte Carlo calculations. In this study we have determined new backscatter factors by both experimental and Monte Carlo methods, and compared them with existing backscatter factors published in the AAPM TG-61 protocol. The purpose of this study is twofold: (1) to evaluate the overall effectiveness of using Gafchromic EBT film for backscatter factor measurements and (2) to determine whether existing Monte Carlo-calculated backscatter factors need to be updated. We measured backscatter factors using Gafchromic EBT film for three field sizes (2, 4 and 6 cm diameter cones) and three kilovoltage beam qualities, including 280 kVp for which similar measurements have not previously been reported. We also present new Monte Carlo-calculated backscatter factors obtained using the EGSnrc/BEAMnrc code system to simulate the Pantak kilovoltage x-ray unit used in our measurements. The results were compared with backscatter factors tabulated in the AAPM TG-61 protocol for kilovoltage x-ray dosimetry. The largest difference between our measured and calculated backscatter factors and the AAPM TG-61 values was found to be 2.5%. This agreement is remarkably good, considering that the AAPM TG-61 values consist of a combination of experimental and Monte Carlo calculations obtained over 20 years ago using different measurement techniques, as well as older Monte Carlo code and cross-section data. Furthermore, our Monte Carlo-calculated backscatter factors agree within 1% with the AAPM TG-61 values for all beam qualities and field sizes. Our Gafchromic film measurements had slightly larger differences with the AAPM TG-61 backscatter factors, up to approximately 2% for the 6 cm diameter cone at a beam quality of 50 kVp. The largest difference in backscatter factors, of 2.5%, was found between Monte Carlo-calculated and Gafchromic film-measured data for the 100 kVp x-ray beam with the 4 cm diameter cone. The differences in backscatter factors between the three data sets (measurements, calculations and published values) are all within the uncertainties from our Gafchromic film measurements and Monte Carlo calculations. Our results demonstrate the suitability of using Gafchromic EBT film to measure equipment-specific backscatter factors for kilovoltage x-ray beams over the entire energy range and also confirm that backscatter factors published in kilovoltage dosimetry protocols still remain valid.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».