Dynamics of fines deposition in an alternating semifluidized bed
Notice bibliographique
Résumé
Abstract A semifluidized bed was proposed to allay bed plugging during the filtration of fines‐hydrocarbon suspensions. Mitigation of plugging was allowed by alternating semifluidization during capture with unconstrained fluidization for removal of deposits. Solids holdup conditions were established to prevent deposition in the fluidization section. The cyclic parameters were varied to allow efficient removal of deposits during washing. Analysis with a filtration model accounting for solids detachment in the fixed bed section revealed that the fluidization section favored growth of aggregate size entering the fixed bed. Analysis of the split ratios between fixed and fluidized bed heights revealed that the shallowest fluidization sections delayed deposition in the fixed bed. In cyclic operation, reversibility of the semifluidized bed was best recovered via gas injection during the washing stages. However, the filtration times in successive cycles shortened with increasing washing times but lengthened with increasing the washing superficial suspension velocity. © 2008 American Institute of Chemical Engineers AIChE J, 2008
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».